Sharp UX-2200CM Service Manual page 26

Hide thumbs Also See for UX-2200CM:
Table of Contents

Advertisement

LJX-22oocMu/cMC
Fo-215clcMu/cMc
SW9 No. 8
Bwy
tone detection (after auto dial)
Use to set busy tone detection in auto dialing.
SW10 No. 1, No.
2
Resewed
set to '0".
SW10 No. 3, No. 4 Cl oft detection timer (Distinctive ring setting off
only)
Set
the
minimum time period of Cl signal interruption which affords to be
judged as a Cl
OFF
section.
+------I
I-B-I
1
l-l
t-l
I-
I
4oomsac
2000msec
0
Q
SW10 No. 5 - No. 6 Distinctive ringing setting (Factory setting:OFF)
When the ringing setting is turned off, all of the Cl signal are received.
When any of the standard, and ring patterns 1 through 3 is selected for
the ringing setting, only the selected
Cl
signal is received.
Cl signal patterns
The Cl signal patterns
of the standard
and ring pat-
terns 1 through7. The standard pattern is the conventional
one.
2s
4s
iTANDARD
Fe--d
RING
OXIS
0.8s
'ATERN
1
for USA
0.4s
4s
1s
1s
I
1s
3s
RING
0.3s
1s
0.3s
'AlTERN
1
u
for USA
0.2s
0.2s
4s
RING
0.4s 0.4s O.&S
AlTERN
3
1
for USA
0.2s 0.2s
4s
RING
1s
1s
AlTERN
11 CANADA
1
0.5s
3.5s
RING
0.5s
1s
0.5s
AllERN
2
,r CANADA
0.5s
0.5s
3s
RING
0.5s
0.5s
1s
AllERN
3
lr CANADA
0.5s
0.5s
3s
SW11 No. 1, No. 2 End buzzer
The sounding length of the buzzer for normal end of operation is set.
SW11 No. 3 Communication error treatment in RTN sending mode
(reception)
The operation
is set when the RTN signal is received in the G3 trans-
mission mode.
SW11 No. 4 CNG transmission
When set to "O", this model allows CNG transmission
by pressing the
Start key in the key pad dialing mode. When set to "l", CNG transmis-
sion in the key pad dialing mode cannot be performed. In either case.
CNG transmission
can be performed in the auto dial mode.
SW11 No. 5 Error criterion
Used to select error criterion for sending back RNT when receiving im-
age data.
SW11 No. 6 Pulse to Tone change by x key
When setting to 1, the mode is changed by pressing the % key from the
pulse dial mode to the tone dial mode.
SW11 No. 7 CNG transmission in manual transmission
In case of CCllT
there is no need to send the CNG signal in manual
transmission
mode .This setting allows this signal to be sent in case of
manual transmission
SD
as to inform the other party's machine that the
machine is FAX.
SW11 No. 6 Reeetved
Set to "0".
SW12 No. 1 - No. 6 DTMF signal transmission
level (Low)
The transmission
level of DTMF signal is adjusted. (lower frequency)
00000 : 0 dBm
J
11111
:
-15.5dBm
SW12 No. 6 - No. 6
not used
Set to "0".
SW13 No. 1 - No. 5 DTMF signal transmission level (High)
The transmission
level of DTMF signal is adjusted. (higher frequency)
0OOOO:OdBm
3.
11111
:
-15.5 dBm
SW13 No. 6 - No. 6
not used
Set to "0".
SW14 No. 1 - No. 3 Reserved
Set to "0".
SW14 No. 4, No. 5 Reserved
Set to "1".
SW14 No. 6 - No. 6 Resewed
Set to "0".
SW15 No. 1 - No. 6 Reserved
Set
tD "0".
SW16 No. 1 Reserved
Set to "1 I'.
SW16 No. 2 - No. 4 Reserved
set to '0".
SW16 No. 5 Reserved
Set to '1".
SW16 No. 6 - No. 6 Reserved
Set to "0".