Lp Conversion Instructions - Quadra-Fire REMINGTON QFP40 Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

NOTE: If converting this unit to propane, do so at this point of installation.
The installation of this conversion kit must only be undertaken by a quali-
CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND TURN OFF
GAS SUPPLY TO UNIT BEFORE PROCEEDING.
Valve Regulator Tower
1.
Turn control knob to the OFF position and shut off the gas supply to the valve.
2.
Using a Torx TH20, or slotted screwdriver, remove the three pressure regulator
mounting screws (A), pressure regulator tower (B), and diaphragm (C). (You may
wish to retain these items for converting back to original gas if necessary.)
3.
Insure that the rubber gasket (D) is properly positioned and install the new HI/LO
pressure regulator assembly to the valve using the new screws (E) supplied with
the kit. Tighten screws securely. (Reference torque = 25 in/lb)
4.
Install the enclosed identification label (F) to the valve body where it can be seen.
Page 14
REMINGTON QFP40 Direct Vent FIREPLACE

LP CONVERSION INSTRUCTIONS

Part # 842-4470 is required for this procedure.
WARNING !
fied and certified gas appliance installer.
A
B
C
E
D
F
250-4721 JUNE 2001