1. Before installing the Pump and Cap Assembly identify the Tube Receptacles where the Pump
Tubes must be inserted.
2. Before installing the Pump and Cap Assembly, note this detail.

Pump and Cap Installation

Pump and Cap Installation
Blow up view
Tubes go here
The Plastic Tray that sits under
the Pump, and that the Tubes
are inserted into, has one corner
that sits on top of the Pump /
Cap Assembly Frame.
View from the bottom. Note the
Plastic Tray is on top of the
Frame Mount.
View from the back of the Printer.
The Plastic is on top of the
Frame.