Stylus Pro 4000 Field Repair Guide
Purpose: The Platen Gap Adjustment sets the physical platen gap to the correct distance.
1. Remove the Left Side Cover.
1. Open the Top Cover, and defeat the Top Cover Sensor by wedging something (paper) against
the Sensor.
2. Loosen the 2 Screws that fasten the Platen Gap Step Locking Mechanism, located on the left
side of the Rear Carriage Rail.
Platen Gap Adjustment
Platen Gap Adjustment
Printer Component,
Software Item,
Wedge something against
the Top Cover Sensor, to
simulate a closed Top
Cover.
Loosen 2 Screws
LCD Display,
Printer Button
4/28/05