Multi Sensor Position Adjustment

Note: This mechanical adjustment fixes the physical position of the Multi Sensor.
1. Rotate the Rear Carriage Rail until the Platen Position Stopper is in the first Detent.
First Detent.
2. Place a 3mm feeler gauge on the Platen as shown.
3 mm feeler gauge.