7. HOW TO INSTALL THE WEEKLY TIMER
(OPTIONAL CONTROLLER)
Do not supply power to the
unit or try to operate it until
the tubing and wiring to the
outdoor unit is completed.
Accessories
No.
Accompanying parts
Q'ty
Weekly timer
1
1
Connecting wiring
length 1.2 m
2
2
Screws M4 x 25
3
2
Wooden screws
4
2
CAUTION
The mounting position for the weekly timer should be
located in an accessible place for control. Never
cover the weekly timer or recess it into the wall.
(1) Remove the flat-top screw on the bottom of the
back case. When you open up the decorative
cover, you will see two gaps under the weekly
timer. Insert a coin into these gaps and remove
the back case. (Figs. 7-1, 7-2)

7-1. When Using a Wall Box for Flush Mounting

If local codes allow, this weekly timer can be
mounted using a conventional wall box for flush
mounting.
(2) Attach the back case with the 2 small screws
provided. Using a screwdriver, push open the
cut-outs on the back case. These holes are for
screws. Use the spacers and take care not to
tighten the screws excessively. If the back case
does not sit well, cut the spacers to a suitable
thickness. (Fig. 7-1)
(3) Connect the 4 wires to the weekly timer 4P
terminal base (see next page).
(4) To finish, fit the back tabs of the back case into
the weekly timer and mount it using the flat-top
screw.
No.
Accompanying parts
Q'ty
Spacer
5
2
Clampers
6
2
Operation manual
7
1
Installation manual
8
1
Do not twist the control
wiring with the power
wiring or run it in the
same metal conduit,
because this may cause
malfunction.
Install the weekly timer
away from sources of
electrical noise.
Install a noise filter or
take other appropriate
action if electrical noise
affects the power supply
circuit of the unit.
Switch box for 1 (no cover)
or switch box for 2 (no cover)
M4 x 25
Screws (2)
Weekly
timer
Decorative
cover
Decorative
cover
Mounting dimensions
for continuous installation
92 mm or more
from the wall
Spacer
90 mm or more
Wiring outlet
Wall box
For vertical continuous installation, the space
between the weekly timer and the remote controller
must be 25 mm or more.
67
S4179544
Switch box
Spacer
Under case
(Back case)
Flat-top
screw
0157_M _I
Fig. 7-1
Control panel
Gap
Gap
Coin
0158_M_I
Fig. 7-2
125 mm or more
125 mm or more
2
0171_M_I
0 0 0 0 0
C
- - - - -
RC
= = = = =
WT