Outdoor Unit
AVOID:
heat sources, exhaust fans, etc.
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air intake/
exhaust and possible maintenance.
Installation Space
Install the outdoor unit where there is enough space
for ventilation. Otherwise the unit may overheat. Refer
to the figure at right for the minimum space require-
ments regardless of how many units are installed. The
mounting base should be concrete or a similar material
that allows for adequate drainage. Make provisions for
anchor bolts, platform height, and other site-specific
installation requirements.
Do not do any wiring or tubing within 60 cm of the
front panel, because it is needed as a servicing
space for the compressor.
Multiple Installation
Min. 60 cm
Min. 13 cm
Min. 13 cm
Min. 100 cm
Min. 50 cm
Min. 60 cm
Min. 60 cm
Min. 60 cm
Min. 50 cm
Refer to the above diagram when installing more than
1 unit. Take into consideration nearby pedestrian
walkways and ventilation requirements when installing.
*Consult a company that sells the unit about multiple
installation.

70, 90 Type

Min. 13 cm
Min. 13 cm
Min. 60 cm
Min. 50 cm
0026_M_I
Hot air
Three units placed adjacently
Min. 50 cm
Min. 13 cm
17
S4179544
Exhaust fan
Heat
source
Out-
door
unit
0024_C_I
Fig. 2-9
Min. 50 cm
Min. 13 cm
Fig. 2-10
0025_C_I