Floor-Standing Type (F Type); Concealed Floor-Standing Type (Fm Type); Required Minimum Space For Installation And; Dimensions And Part Names - Sanyo SPW-X483GH56 Installation Instruction

Eco multi system air conditioner
Table of Contents

Advertisement

Floor-Standing Type (F Type)

Concealed Floor-Standing Type (FM Type)

3-34. Required Minimum Space for Installation
and Service
Install the unit where cooled or heated air from the unit
can circulate well in the room. Do not put obstacles
which may obstruct the air flow in front of the air intake
and outlet grilles.
NOTE
Ensure that there is space for maintenance of the
electrical component box, air filter and, refrigerant
tubes.

3-35. Dimensions and Part Names

1. Floor-Standing Type (F Type)
1
4-ø12 hole (For fastening the indoor unit to the
floor by screws.)
2
Air filter
3
Refrigerant connection outlet (narrow tube)
4
Refrigerant connection outlet (wide tube)
5
Level adjusting bolt
6
Drain outlet (20 A)
7
Power cord outlet (downward, rear)
8
Refrigerant tubing outlet (downward, rear)
9
Location for mounting the remote controller
(remote controller is attachable in the room)

Table 3-7

Size
A

Type

1065
9, 12
18, 25
1380
36
54
Narrow
B
C
665
632
980
947
C
B
A
Air outlet
Air inlet
54
Fig. 3-105
Horizontal view
min.
10 cm
min. 100 cm
Fig. 3-104
Wide
tube
tube
9.52
12.7
9.52
15.88
161
26 15
57
177
100
230
Side panel
Refrigerant tubing space for downward tubing
615
25 R
155
107
Rear-tube outlet
51
S4179544
Vertical view
min.
10 cm
min. 100 cm
0754_M_I
156
67
76
213
260
205
0755_M _I
7 7 7 7 7
D
8 8 8 8 8
F
9 9 9 9 9
FM