Drive motor
Assembly
Assemble in the reverse order.
1. Fit the drive motor with the four screws and
washers (see fig. below).
2. Run the connection cables in through the
chassis cable duct.
3. Connect the magnetic brake and drive motor
cabling at the contacts on the cabling. These
are positioned on the inside of the chassis,
next to the seat lift/seat tube (see fig.). Fit the
contacts together in their holder.
4. Fit the drive wheel. See page 18.
5. Fit the chassis covers. See page 8-9.
m CAUTION!
Check the function of the brake release after fitting. When
the brakes are released, it should not be possible to drive the
wheelchair.
1
2
Fitting/removing the Drive motor.
29
For this task the following tools are necessary:
1
Allen key 5 mm.
1
Allen key 6 mm.
The contacts are mounted together in a holder.
Item
1
Screw ISO 4762 M6x60 8.8 Fe/Zn
2
Washer, ISO 7089 6 200 HV Fe/Zn 5 C1(6,4x12x1,6)
Drive motor
Description