Permobil M300 Service Manual page 16

Hide thumbs Also See for M300:
Table of Contents

Advertisement

Batteries
Batteries
m WARNING!
Observe care in the use of metallic objects when working
with batteries. A short-circuit can easily cause an explosion.
Always use protective gloves and protective eye-glasses.
The batteries are heavy and must be handled with care.
Used or broken drive batteries should be taken care of in an
environmentally correct manner in accordance with locally
applicable recycling directions.
Replacing the rear battery
1. Place the wheelchair on a level surface.
2. Raise the seat; electric seat lift to the highest
position; fixed seat tube to the service position.
See page 34. If the electric seat lift does
not work normally because the batteries
are discharged or the adjustment device is
defective, the seat can be raised/lowered
manually. See page 31.
3. Switch off the main power switch on the control
panel
4. Switch the main fuse to OFF (see fig. above).
5. Remove the chassis covers. See page 8-9.
6. Remove the electronics by pulling the locking
handles on the left and right handside of the
chassis outwards (see fig. below). Disengage
the tabs before pulling assembly back.
7. If the wheelchair is equipped with seat support,
remove it. See page 36.
Remove the electronics by pulling the lockig handles on the
left and right handside of the chassis outwards.
16
For this task the following tools are necessary:
1
Wrench 10 mm.
Off
Main fuse/battery isolator (On/Off).
On

Hide quick links: