Input/Output Sentences; Sensor 1, Sensor2, And Sensor3 Ports; Pc I/O, Lr Or Ecdis/Radar, Extra I/O And Extra 1 I/O Port - Furuno FA-100 Installation Manual

Uais transponder
Hide thumbs Also See for FA-100:
Table of Contents

Advertisement

3.7 Input/Output Sentences

1) SENSOR 1, SENSOR2, and SENSOR3 ports

These ports can receive IEC61162-1/2 standard data. The transmission rate of
sensor 1, 2, and 3 is selectable from 4800 bps and 38.4 kbps through the menu.
Input sentences are as follows:
2) PC I/O, LR or ECDIS/RADAR, EXTRA I/O and EXTRA 1 I/O ports
These ports can receive or output IEC61162-1/2 standard data. The transmission
rate of signals is selectable from 4800 bps and 38.4 kbps through the menu. The
transmission rate of the EXTRA IO port signal is fixed to 4800 bps.
Input sentences are as follows:
Output sentences are as follows:
20
$xxDTM, $xxGBS, $xxGGA, $xxGLL, $xxGNS, $xxHDT
$xxOSD, $xxRMC, $xxROT, $xxVBW, $xxVTG
Note: The talker of the underlined sentences has priority as
follows:
GN>GP>GL>LC>IN
Other sentences disregard talker.
$xxABM, $xxACA, $xxACK, $xxAIR
$xxBBM, $xxDTM, $xxGBS, $xxGGA
$xxGLL, $xxGNS, $xxHDT, $xxLRF
$xxLRI, $xxOSD, $xxRMC, $xxROT
$xxSSD, $xxVBW, $xxVSD, $xxVTG
Note: The talker of the underlined sentences has priority as
follows:
GN>GP>GL>LC>IN
Other sentences disregard talker.
$AIABK, $AIACA, $AIALR, $AILRF,
$AILR1, $AILR2, $AILR3, $AITXT,
$AIVDM, $AIVDO

Advertisement

Table of Contents
loading

Table of Contents