2. Install the two (2) brackets, using the sheet metal
screws, at the bottom right and left corners of the
unit. (Fig. 27)
Bracket
Sheet Metal
Screws
Fig. 27 Use sheet metal screws to attach brackets to
existing holes under glass frame assembly.
3. Set the glass frame assembly provided with your kit
in front of the glass frame assembly on the unit (the
outside side).
4. Have the machine screws provided with the kit
within reach.
5. Unfasten the two (2) machine screws that secure
the glass frame assembly to the unit and discard.
Slide the glass frame assembly provided with the kit
over the surround around the glass frame assembly
on the side and top.
WARNING: The glass frame assembly provided
with the unit must be left in place for proper opera-
tion. Failure to do so could cause property damage
and malfunction of the unit.
6. Fasten the two (2) long machine screws at the top
through the two (2) glass frame assemblies and
fasten the two (2) short machine screws at the
bottom right and left corner into the bracket installed
earlier.
20007172
Chateau
for Vertical Venting Application
The primary purpose for the vent restrictor is to regain
flame height under certain venting conditions as
outlined below.
NOTE: The joints of the inner pipe (flue pipe) must be
taped with 550°F or higher temperature metal adhesive
tape that meets the requirements of F.A.R. 25.853(a).
High temperature sealant milpack or stove cement of
550°F or higher could be used instead. The joints of
The outer pipe (fresh air pipe) must be taped with
315°F or higher temperature metal adhesive tape or
the use of high temperature milpack or stove cement
would be applicable. When using the unitized 30°, 45°
FP1481
or 90° elbows, apply 1/4" bead of high temperature,
550°F or higher, sealant (milpack or stove cement) to
the joint of the inner pipe (flue pipe) and the straight
section as it is impossible to be taped. The outer pipe
must be taped with 315°F high temperature metal
adhesive tape for proper sealing.
For vertically venting either propane or natural gas
units, with vertical vent heights of 12' (3.7m) or greater,
(measured from the top of the flue collar) the restrictor
plate as supplied with this unit should be used. (Fig. 28)
Refer to Page 21, Figure 37 for restrictor plate
installation.
DVT38S2 - Natural or LP
Use 6³⁄₄"
FP1461
Fig. 28 Restrictor plate use in straight up installation.
For vertical venting configurations that include a
minimum vertical rise of 12' (3.7m) and a maximum
horizontal offset of 10' (3m) the 4¹⁄₂" restrictor plate
supplied with this unit should be used on LP unit only.
(Fig. 29) Refer to Page 21, Figure 37 for restrictor plate