Sidewall Installation With Staionary Glass Facing Outside - Majestic Vermont Castings Chateau DVT38S2 Installation Instructions And Homeowner's Manual

Direct vent decorative gas appliance
Table of Contents

Advertisement

Sealing firestop gaps with high temperature seal-
ant will restrict cold air being drawn in around
fireplace.
STEP 8
Guide the vent terminations 8" and 11" collars into their
respective vent pipes. Double check that the vent pipes
overlap the collars by 2" (50mm). Secure the termina-
tion to the wall with screws provided and caulk around
the wall plate to weatherproof. (Fig. 24) As an alterna-
tive to screwing the termination directly to the wall you
may also use expanding plugs or an approved exterior
construction adhesive.
Fig. 22 Horizontal length requirement.
Fig. 23 Through the wall.
20007172
X
FP1457
FP1458
Chateau
Decorative Gas Appliance
Fig. 24 Secure termination to wall.
Support horizontal pipes every 3' (91 cm)
with metal pipe straps.
Check fireplace to make sure it is levelled
and properly positioned.
Sidewall Installation with
Stationary Glass Facing Outside
CAUTION: Unit must be installed with stationary
glass facing outside. (Control panel assembly will
be located on the left side of the unit when facing
the unit form inside house.)
Failure to do so will result in a major reconstruc-
tion and CFM will not be responsible for costs
associated with incorrect installation.
CAUTION: Control panel assembly must
be installed on the inside of the house
and not on the outside.
STEP 1
Locate vent opening on the wall. It may be necessary to
first position the fireplace and measure to obtain hole
location. Depending on whether the wall is combustible
or noncombustible, cut opening to size. (Fig. 19)
For combustible walls first frame in opening.
Combustible Walls: Cut a 16¹⁄₄"H x 16¹⁄₄" W (413mm x
413mm) hole through the exterior wall and frame as
shown.
Noncombustible Walls: Hole opening must be 11¹⁄₄"
(286mm) in diameter.
STEP 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 12"/305 mm).
Assemble sleeve using #8 sheet metal screws (sup-
plied). (Fig. 20) Install firestop assembly. (Fig. 30)
FP1460
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents