Majestic DVLB7 Series Manual

Majestic DVLB7 Series Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Quick Links

DVBL7 Series
Direct Vent Gas Fireplace
models:
300DVBLn/pV7;n/pSc7
400DVBLn/pV7;n/pSc7
500DVBLn/pV7;n/pSc7
warnInGS
IF the InFormatIon In theSe InStructIonS
are not FoLLoweD exactLy, a FIre
or expLoSIon may reSuLt cauSInG
property DamaGe, perSonaL Injury or
LoSS oF LIFe.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
what to Do IF you SmeLL GaS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
warnInG: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSa
only) or mobile home, where not prohibited by
local codes.
this appliance is only for use with the type of
gas indicated on the rating plate. this appliance
is not convertible for use with other gases,
unless a certified kit is used.
* aftermarket: completion of sale, not for purpose of
resale, from the manufacturer.
All manuals and user guides at all-guides.com
Installation and
Operating
Instructions
Due to hIGh temperatureS, the appLIance
ShouLD Be LocateD out oF traFFIc anD
away From FurnIture anD DraperIeS.
chILDren anD aDuLtS ShouLD Be aLerteD
to the haZarDS oF hIGh SurFace
temperature anD ShouLD Stay away to
aVoID BurnS or cLothInG IGnItIon.
younG chILDren ShouLD Be SuperVISeD
when they are In the Same room aS the
appLIance.
cLothInG or other FLammaBLe materIaL
ShouLD not Be pLaceD on or near the
appLIance.
Keep the room area cLear anD Free
From comBuStIBLe materIaLS, GaSoLIne,
anD other FLammaBLe VaporS anD
LIquIDS.
InStaLLer: Leave this manual with the appliance.
conSumer: retain this manual for future refer-
ence.
743000
BLDV 7 cover
74D3001 5/10 Rev. 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVLB7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic DVLB7 Series

  • Page 1 All manuals and user guides at all-guides.com DVBL7 Series Direct Vent Gas Fireplace models: 300DVBLn/pV7;n/pSc7 400DVBLn/pV7;n/pSc7 500DVBLn/pV7;n/pSc7 warnInGS IF the InFormatIon In theSe InStructIonS are not FoLLoweD exactLy, a FIre or expLoSIon may reSuLt cauSInG property DamaGe, perSonaL Injury or LoSS oF LIFe.
  • Page 2: Table Of Contents

    DVBL7 Series Gas Fireplace contentS thank you and congratulations on your purchase of a majestic Fireplace. pLeaSe reaD the InStaLLatIon anD operatIon InStructIonS BeFore uSInG the appLIance! Important: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    All manuals and user guides at all-guides.com Important SaFety InFormatIon DVBL7 Series Gas Fireplace InStaLLer owner Please leave these instructions with the appliance. Please retain these instructions for future reference. • read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.
  • Page 4: Code Approval

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace Important SaFety InFormatIon & coDe approVaL 1. Do not use this fireplace to cook food or burn paper Important: or other objects. pLeaSe reaD the FoLLowInG careFuLLy 13. Never place anything on top of fireplace. It is normal for fireplaces fabricated of steel to give 14.
  • Page 5: Product Specifications

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace proDuct FeatureS proDuct SpecIFIcatIonS hIGh eLeVatIonS • This appliance has been certified for use with either Input ratings are shown in BTU per hour and are certified natural or propane gas. See appropriate data plates. without deration for elevations up to 4,500 feet (1,370 •...
  • Page 6: Pre-Installation Information

    All manuals and user guides at all-guides.com pre-InStaLLatIon InFormatIon DVBL7 Series Gas Fireplace Rough 7" Dia. Opening Depth 4" Dia. 1/2” or 5/8” (13 or 16 mm) R - Rough Opening Width Rough Opening Height Figure 2 - Fireplace Specifications and Framing Dimensions Gas Line Access 300DVBL 400DVBL 500DVBL 743000 34Z\x"...
  • Page 7: Before You Start

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace pre-InStaLLatIon InFormatIon BeFore you Start FIreBox FramInG Read this homeowner manual thoroughly and follow all Firebox framing can be built before or after the appliance instructions carefully. Inspect all contents for shipping is set in place.
  • Page 8: Fireplace Location

    All manuals and user guides at all-guides.com pre-InStaLLatIon InFormatIon DVBL7 Series Gas Fireplace FIrepLace LocatIon Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e.
  • Page 9: Clearances

    All manuals and user guides at all-guides.com cLearanceS DVBL7 Series Gas Fireplace cLearanceS to comBuStIBLeS Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring.
  • Page 10: Securing Fireplace To Floor Or Framing

    All manuals and user guides at all-guides.com SecurInG FIrepLace to FLoor or FramInG DVBL7 Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 11: Vent Installation

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace VentInG InStaLLatIon InFormatIon read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
  • Page 12 All manuals and user guides at all-guides.com VentInG InStaLLatIon InFormatIon DVBL7 Series Gas Fireplace GeneraL VentInG InFormatIon - termInatIon LocatIon INSIDE  CORNER DETAIL  G  V  H  A  D  E  L  C  B  B  V  Fixed B  V  Closed V  Fixed Operable Closed F ...
  • Page 13: Assembling Vent Pipes

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace VentInG InStaLLatIon InFormatIon Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2"...
  • Page 14: How To Use The Vent Graph

    All manuals and user guides at all-guides.com VentInG InStaLLatIon InFormatIon DVBL7 Series Gas Fireplace twISt LocK pIpeS When using twist lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system.
  • Page 15: Vent Pipe Clearances To Combustibles

    All manuals and user guides at all-guides.com Vent InStaLLatIon DVBL7 Series Gas Fireplace horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall.
  • Page 16: Vertical Sidewall Applications

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace Vent InStaLLatIon VertIcaL SIDewaLL appLIcatIon example: According to the vent graph (Page 15) the minimum clearance between vent pipes and combus- maximum horizontal vent length in a system with a 7Z\x’ tible materials is 3"...
  • Page 17 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace Vent InStaLLatIon VertIcaL SIDewaLL InStaLLatIon - twISt LocK pIpe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation.
  • Page 18: Below Grade Installation

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace Vent InStaLLatIon Sealing vent pipe and firestop gaps with high tem- perature sealant will restrict cold air being drawn in around fireplace. 4" Flex Step 7 12" Vent Pipe (305 mm) Guide the vent terminations 4”...
  • Page 19: Vertical Through-The-Roof Applications

    All manuals and user guides at all-guides.com Vent InStaLLatIon DVBL7 Series Gas Fireplace . Remove soil to a depth of approximately 16” (406 mm) VertIcaL throuGh-the-rooF below base of snorkel. Install drain pipe. Install window appLIcatIon well (not supplied). Refill hole with 1” (305 mm) of his gas fireplace has been approved for: coarse gravel leaving a clearance of approximately 4”...
  • Page 20: Installation

    All manuals and user guides at all-guides.com Vent InStaLLatIon DVBL7 Series Gas Fireplace attic Insulation Shield (7DV1aIS) 1 +  + 3 + 4 = 70° upper Floor Figure 24 - 11” Maximum Elbow (79 mm) Usage ceiling Installation 12” Min. FP109 Joist FP1179...
  • Page 21 All manuals and user guides at all-guides.com Vent InStaLLatIon DVBL7 Series Gas Fireplace Horizontal Overhang 2 ft.  2 ft. Min. Min. Lowest Discharge Opening roof pitch h (feet) Termination Flat to 6/1 Vent Over 6/1 to 7/1 1.5 Over 7/1 to 8/1 Over 8/1 to 9/1 Storm Collar Over 9/1 to 10/1 FP1971...
  • Page 22: Fireplace Installation

    All manuals and user guides at all-guides.com FIrepLace InStaLLatIon DVBL7 Series Gas Fireplace checK GaS type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.
  • Page 23 All manuals and user guides at all-guides.com FIrepLace InStaLLatIon DVBL7 Series Gas Fireplace a manual shutoff valve must be installed only persons licensed to work with gas upstream of the appliance. union tee and piping may make the necessary gas plugged 1/8”...
  • Page 24: Electrical Installation

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace mILLIVoLt - checKInG GaS preSSure and eLectrIcaL InStaLLatIon 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, Stop! Do not install the appliance.
  • Page 25: Glass Removal

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace GLaSS remoVaL GLaSS Frame remoVaL 1. Remove access panel by lifting up and out. . Release two clamps (500 model has three clamps) on bottom of fireplace. Figure 33 3.
  • Page 26: Remote Wall Switch Installation

    All manuals and user guides at all-guides.com remote waLL SwItch & BLower InStaLLatIon DVBL7 Series Gas Fireplace remote waLL mounteD SwItch A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a Do not connect wall switch to (110 V) junction box at the desired location on the wall.
  • Page 27 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace optIonaL Fan/BLower SyStem 3. Remove logs. 4. Remove grate from engine by lifting up. 5. Remove hearth brick and wall brick panels. 6. Disconnect the gas line to the valve. 7.
  • Page 28 All manuals and user guides at all-guides.com optIonaL Fan/BLower SyStem DVBL7 Series Gas Fireplace Start Position Installed Position KT505 Figure 38 - Blower Installation Position note: Some older units are not equipped with mounting brackets. Velcro and magnets are used to mount blowers to sidewall and floor. KT505 install blower clip...
  • Page 29: Operating Instructions (Milli-Volt)

    All manuals and user guides at all-guides.com operatInG InStructIonS (mILLI-VoLt) DVBL7 Series Gas Fireplace For your SaFety reaD BeFore LIGhtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a.
  • Page 30: Lighting Pilot

    All manuals and user guides at all-guides.com operatInG InStructIonS (mILLI-VoLt) DVBL7 Series Gas Fireplace LIGhtInG pILot For the FIrSt tIme approVeD LeaK teStInG methoD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: Do not spray solution onto...
  • Page 31: Lighting Burner

    All manuals and user guides at all-guides.com operatInG InStructIonS (mILLI-VoLt) DVBL7 Series Gas Fireplace LIGhtInG Burner maIn Burner SwItch The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 32: Checking Gas Pressure - (Signature Command System)

    All manuals and user guides at all-guides.com SIGnature commanD - checK GaS preSSure and eLectrIcaL InStaLLatIon DVBL7 Series Gas Fireplace 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, Stop! Do not install the appliance.
  • Page 33: Junction Box Wiring

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace SIGnature commanD - eLectrIcaL InStaLLatIon junctIon Box wIrInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes.
  • Page 34: Signature Command Wiring Diagram

    All manuals and user guides at all-guides.com eLectrIcaL InStaLLatIon DVBL7 Series Gas Fireplace Optional To Junction Box AC Module in Fireplace Pilot Optional White Light Black Optional White Blower Black White Optional Black Aux. Green Connector Pin To Control Board Input 300 Watt Max. Each Optional A/C Module Replaces 6V Adapter When Used RF Receiver ON/OFF Button Control Board 6V AC Black / Thermopile Adapter Red / Thermopile...
  • Page 35: Optional Fan/Blower System (Scs)

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace optIonaL Fan BLower SyStemS electrical Grounding Instructions: this electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical...
  • Page 36: Blotsdv

    All manuals and user guides at all-guides.com optIonaL Fan BLower SyStemS DVBL7 Series Gas Fireplace BLotSDV automatIc thermoStat BLower 120VAC Receptacle  Junction  BLACK GREEN WHITE BLACK WHITE BLACK BLACK Speed Control  Figure 51 - BLOTSDV Blower Wiring Diagram FP685 Before installing the blower, wire the receptacle into an electrical circuit.
  • Page 37: Operating Instructions (Scs)

    All manuals and user guides at all-guides.com operatInG InStructIonS - SIGnature commanD DVBL7 Series Gas Fireplace For your SaFety reaD BeFore LIGhtInG If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie.
  • Page 38: Operating Instructions

    All manuals and user guides at all-guides.com operatInG InStructIonS - SIGnature commanD DVBL7 Series Gas Fireplace operatInG InStructIonS 1. Stop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
  • Page 39: Signature Command System Operation

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace SIGnature commanD SyStem operatIon InStructIonS To Thermopile FeatureS RF Receiver ON/OFF To Sensor command center To Sparker • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ NG/LP Buzzer) Conversion...
  • Page 40 All manuals and user guides at all-guides.com SIGnature commanD SyStem operatIon InStructIonS DVBL7 Series Gas Fireplace SyStem conFIGuratIon/Setup All System configuration/setup is done on the Command Center. note: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center.
  • Page 41 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace SIGnature commanD SyStem operatIon InStructIonS FunctIonS/operatIon turning on the fireplace 1. Turn on the master switch and wait for a beep. . Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below).
  • Page 42: Final Installation

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace LoG & rocK wooL InStaLLatIon hearth BrIcK pLacement Place the hearth brick centered in front of burner and slide back until it hits the stops on the right and left of burner. rocK wooL pLacement 1.
  • Page 43 All manuals and user guides at all-guides.com FInaL InStaLLatIon DVBL7 Series Gas Fireplace 5. Place the middle cross log (#6) by matching the rectangular notch on the bottom of this log with the rectangular protrusion of the rear log toward the left. The narrow pointed end will line up between the second left tong and the middle tong on the grate.
  • Page 44: Cleaning And Maintenance

    All manuals and user guides at all-guides.com cLeanInG anD maIntenance DVBL7 Series Gas Fireplace Sensor turn off gas before servicing fireplace. It is recommended that a qualified service Signature Thermopile technician perform these check-ups at the command beginning of each heating season System pilot Burner, pILot anD controL compart- ment...
  • Page 45: Vent System

    All manuals and user guides at all-guides.com cLeanInG anD maIntenance DVBL7 Series Gas Fireplace Vent SyStem The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 46: Troubleshooting Standing Pilot Ignition

    All manuals and user guides at all-guides.com trouBLeShootInG DVBL7 Series Gas Fireplace StanDInG pILot IGnItIon mILLIVoLt SyStem Symptom poSSIBLe cauSe actIon 1. Spark ignitor will A. Wire disconnected. A. Open door and check to make sure wire is connected not light pilot after to ignitor.
  • Page 47 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace trouBLeShootInG StanDInG pILot IGnItIon mILLIVoLt SyStem Symptom poSSIBLe cauSe actIon 4. Frequent pilot A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame outage problem.
  • Page 48: Signature Command System

    All manuals and user guides at all-guides.com trouBLeShootInG DVBL7 Series Gas Fireplace SIGnature commanD SyStem OPERATION FAULT DIAGNOSIS ACTION Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Change batteries Battery voltage low? Center and plug in the AC board No beep in about the control 8 seconds...
  • Page 49: Replacement Parts

    All manuals and user guides at all-guides.com repLacement partS DVBL7 Series Gas Fireplace FIreBox componentS ref. Description qty. 400DVBL 500DVBL Junction Box Assy (not shown) 6D18K 6D18K Sheet Metal Base 74D0514 74D0515 Glass Frame Assy 74D0096K 74D011TK 743000 Control Cover 74D0038K 74D0119 BLDV 7 parts...
  • Page 50: Standing Pilot Millivolt Control

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace repLacement partS StanDInG pILot — mILLIVoLt controL 11,12,13,14 743000 BLDV millivolt parts 74D3001...
  • Page 51 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace repLacement partS StanDInG pILot — mILLIVoLt controL ref. Description qty. 400DVBLnV7 400DVBLpV7 500DVBLnV7 500DVBLpV7 1. Gas Valve Assy 37D0117 37D0118 37D0117 37D0118 . Pilot Assy 37D0018 37D0019 37D0018 37D0019 C.
  • Page 52 All manuals and user guides at all-guides.com repLacement partS DVBL7 Series Gas Fireplace SIGnature commanD SyStem 13, 14, 15, 16, 17 743000 BLDV SC parts 74D3001...
  • Page 53: Signature Command System

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace repLacement partS SIGnature commanD SyStem Item Description qty. 400DVBLnS7 400DVBLpS7 500DVBLnS7 500DVBLpS7 Gas Valve Assembly 80D0001 80D000 80D0001 80D000 Pilot Assembly 80D0006 80D0007 80D0006 80D0007 Control Box 80D0018 80D0019 80D0018 80D0019 Command Center...
  • Page 54: Logs

    All manuals and user guides at all-guides.com repLacement partS DVBL7 Series Gas Fireplace LoGS ref. Description qty. 400DVBL 500DVBL Rear Log #1 74D0059 74D0059 743001 Top Right Log # 74D0060 74D0060 DVBL logs Front Upper Log #3 74D0061 74D0061 Right Front Log #4 74D006 74D0157 Left Front Log #5...
  • Page 55: Venting Components

    All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace VentInG componentS VertIcaL VentInG Description model number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar 7TDVSKV (flashing NOT included) Vertical Vent Termination w/ Storm Collar - 8 pack 7TDVSKV/8 (flashing NOT included) Vertical Vent Termination w/ 1/1 - 6/1 Flashing, Storm...
  • Page 56 All manuals and user guides at all-guides.com VentInG componentS DVBL7 Series Gas Fireplace horIZontaL VentInG Description model number Horizontal Vent Termination Kits Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10"...
  • Page 57 All manuals and user guides at all-guides.com DVBL7 Series Gas Fireplace 74D3001...
  • Page 58 All manuals and user guides at all-guides.com requirements for the commonwealth of of eight (8) feet above grade directly in line with the exhaust DVBL7 Series Gas Fireplace vent terminal for the horizontally vented gas fueled heating massachusetts appliance or equipment. The sign shall read, in print size no This product must be installed by a licensed plumber or less than one-half (1/) inch in size, “GaS Vent DIrectLy gas fitter when installed within the Commonwealth of...
  • Page 59: Warranty

    All manuals and user guides at all-guides.com LImIteD LIFetIme warranty poLIcy DVBL7 Series Gas Fireplace LIFetIme warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe year warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 60: Enereguide Efficiencies

    All manuals and user guides at all-guides.com Based on CSA P.4.1-09 efficiency ratings model enerGuide ratings Fireplace efficiency (%) 400DVBLNV7 63.8 400DVBLPV7 60. 400DVBLNSC7 68.1 400DVBLPSC7 6.8 500DVBLNV7 61.1 Recherchez dans la brochure 500DVBLPV7 64.9 les caractéristique de rendement 500DVBLNSC7 64.1 énergétique de foyer au gaz 500DVBLPSC7 67.9 Énerguide...

Table of Contents