All keypads provide complete information and control of the alarm panel. The panel can be completely programmed
via any keypad on the system. LED keypads provide function indicator lights and individual zone indicator lights for
the alarm circuits. The LCD keypad provides function indicator lights and word descriptions for zone status.
The following sections describe how to arm, disarm and perform other keypad functions.
3.1

Access Codes

All 37 access codes have the ability to arm/disarm any Partition(s) it is enabled for and to activate the PGM Outputs
using the [✱][7] commands (See Section 3.4 "[ ✱ ] Commands, [ ✱ ][7]") .
Additional access code attributes are also programmable. Attributes determine what abilities the code will have.
To program each attribute;
1. Enter [✱] [5] [Master Code] [9] to enter the attribute programming mode.
2. Enter the 2-digit number of the access code you want to edit.
3. Enter the attribute number to toggle it on or off.
The programmable attributes are as follows:
• Attribute 1: Partition 1 Operation enabled
• Attribute 2: Partition 2 Operation enabled
• Attribute 3: Zone Bypass enabled
This attribute allows the user to bypass zones.
• Attribute 4: Escort5580 Remote Access
This attribute allows the user to access the security system via the Escort, if installed.
• Attribute 5: Downlook Remote Trigger to Telephone Number 1
For use with the Escort5580 and the PC5108L/DLM-4L (see the PC5108L Installation Manual for details).
• Attribute 6: Downlook Remote Trigger to Telephone Number 2
For use with the Escort5580 and the PC5108L/DLM-4L (see the PC5108L Installation Manual for details).
"Master Code" attributes cannot change. By default, each code has the attributes of the code used to
"Master Code" attributes cannot change. By default, each code has the attributes of the code used to
"Master Code" attributes cannot change. By default, each code has the attributes of the code used to
"Master Code" attributes cannot change. By default, each code has the attributes of the code used to
"Master Code" attributes cannot change. By default, each code has the attributes of the code used to
pr pr pr pr program it.
ogram it.
ogram it.
ogram it.
ogram it.
The available access codes are as follows:
General Access Codes - Access Codes [01] to [32]
Each access code can be used to arm and disarm the system. Enable any of the access code attributes to allow
access to the above-mentioned functions (access code attributes 1-6).
Duress Codes - Access Codes [33] and [34]
When a Duress Code is used to perform any function the panel will report a Duress Reporting Code (See
Section 5.7 "Communicator - Reporting Codes") .
Partition Master Codes - Access Codes [41] and [42]
Partition Master Codes can program additional access codes and the Duress Code for their Partition.
System Master Code - Access Code [40]
By default the System Master Code is enabled to operate on both Partitions and can perform any keypad
function. This code can be used to program all access codes as well as the Partition Master Codes and Duress
Codes.
If the Master Code Not Changeable option is enabled the System Master Code can only be changed using
Installer Programming.
For instructions on programming access codes, see the PC5015 Instruction Manual ("Programming Access
Codes").
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Code Required for Bypass ..................................... Section [015], Option [5]
Master Code Not Changeable option .................... Section [015], Option [6]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Maintenance Code
The maintenance code can only be used to arm and disarm the system. It cannot be used to bypass zones or to
access the Escort5580. The code can only be programmed in Installer's Programming.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Maintenance Code .................................................. [008]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
3.2
Arming / Disarming
The system cannot be armed unless the 'Ready' light is on. If the 'Ready' light is not on make sure all protected
doors and windows are secure and stop movement in areas covered by motion detectors. When the 'Ready' light
is on enter any valid Access Code. As each digit is pressed the keypad will beep. If an incorrect code is entered
the keypad will emit a steady 2 second beep to indicate the code was not correct. If the code is correct but the
'Ready' light was not on the panel will beep six times rapidly followed by a long two second beep to indicate the