Keypad Assignment; Enable Supervision - Member's Mark Power 832 Installation Manual

Liquid propane & natural gas grill
Table of Contents

Advertisement

G
E
T
2.7

Keypad Assignment

There are 8 available addresses for keypads. The LED, LCD5501Z and the LCD5501Z32-433 keypads by default
are assigned to address 1 while the LCD5500(Z) is assigned by default to address 8. Keypads can each be
assigned to a different address (1 to 8) which offers two advantages. The panel can supervise the keypad
connection to indicate a trouble condition if it is removed. Also keypads can be assigned to operate a specific
partition or operate as a global keypad.
2.7.1
How to Assign Keypads
All keypad assignment must be done at each keypad on the system. When using LCD5500(Z)
All keypad assignment must be done at each keypad on the system. When using LCD5500(Z)
All keypad assignment must be done at each keypad on the system. When using LCD5500(Z)
All keypad assignment must be done at each keypad on the system. When using LCD5500(Z)
All keypad assignment must be done at each keypad on the system. When using LCD5500(Z)
keypads, one keypad must r
keypads, one keypad must r
keypads, one keypad must remain in addr
keypads, one keypad must r
keypads, one keypad must r
addr
addr
addr
addr
address.
ess.
ess.
ess.
ess.
To assign a keypad to a address and select the partition it will operate, enter the following:
Step 1 — Enter Installer Programming
Step 2 — Press [000] for Keypad Programming
Step 3 — Press [0] for Partition and Address Assignment
Enter a two digit number to specify the partition and address assignment.
1st digit
Enter 0 for Global Keypad;
Enter 1 for Partition 1 Keypad;
Enter 2 for Partition 2 Keypad
2nd digit Enter 1 to 8 for Address Assignment
Press the [#] key twice to exit programming. Continue this procedure at each keypad until all have been
assigned to the correct address.
2.7.2
How to Program Function Keys
Each of the 5 Function Keys on each keypad may be programmed for different operation on each keypad.
Step 1 - Enter Installer Programming.
Step 2 - Press [000] for Keypad Programming.
Step 3 - Enter [1] to [5] to select Function Key to program.
Step 4 - Enter the 2 digit number, [00] to [25] for option.
Step 5 - Continue from Step 3 until all Function Keys are programmed.
Step 6 - Press [#] key twice to exit Installer Programming.
For a complete list of Function Key options See Section 3.5.1 "Function Key Options" .
2.8

Enable Supervision

Once all the Keybus connections have been made, supervision must be enabled so the panel can indicate a
trouble if a module is removed from the system.
To enable supervision, enter the following at any keypad:
Step 1 - Press [✱] [8] [Installer Code] to enter Installer Programming.
Step 2 - Press [902] to enable supervision. The panel will automatically search for all modules on the system.
Once the search (it will take about 1 minute) is complete enter the following to confirm the modules
on the system.
Step 3 - Press [903] to display all modules.
Zone lights will be turned on according to what modules the panel has found on the system. The LCD keypad
will allow you to scroll through the modules. Refer to the following chart:
Light
[1]
Light
[2]
Light
[3]
Light
[4]
Light
[5]
Light
[6]
Light
[7]
Light
[8]
Light
[9]
Light
[10]
Light
[11]
Light
[12]
If a module is connected but does not show as being present, it may be due to any of the following reasons:
• it is not connected to the Keybus
• if there is a Keybus wiring problem
• if the module is more than 1,000'/305m from the panel
• if the module does not have enough power
• if the PC5132 does not have any devices added
T
I
N
G
emain in address 8. Do not assign mor
emain in addr
emain in addr
emain in addr
Keypad 1 present
Keypad 2 present
Keypad 3 present
Keypad 4 present
Keypad 5 present
Keypad 6 present
Keypad 7 present
Keypad 8 present
Zones 9 to 12 present
Zones 13 to 16 present
Zones 17 to 20 present
Zones 21 to 24 present
WWW.DIYALARMFORUM.COM
S
T
ess 8. Do not assign mor
ess 8. Do not assign mor
ess 8. Do not assign mor
ess 8. Do not assign more than one keypad to the same
Light
[13]
Zones 25 to 28 present
Light
[14]
Zones 29 to 32 present
Light
[15]
N/A (not used)
Light
[16]
N/A (not used)
Light
[17]
Module PC5132 present
Light
[18]
Module PC5208 present
Light
[19]
Module PC5200/5204 present
Light
[20]
Module PC5400 present
Light
[21]
Module PC5928/5936 present
Light
[22]
Alternate Communicator present
Light
[23]
DLM-4L v1.0L present
Light
[24]
Escort5580 module present
9
A
R
T
E
e than one keypad to the same
e than one keypad to the same
e than one keypad to the same
e than one keypad to the same
D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc5015Y0202xc lpY0202xc ng

Table of Contents