When you use a CompacTape III cartridge to make a backup copy of files,
make sure the orange write-protect indicator on the TF85 is off. If the
indicator is not off, check for any of the write-protect conditions described
above. Change the switch setting and/or operating system restriction as
necessary. Do not begin your operation until the write-protect indicator
goes off.
Do not touch the exposed surface of the tape.
Do not drop the tape cartridge. The impact from a fall can damage the
tape cartridge.
Allow new tapes to stabilize at room temperature for 24 hours before
using them.
Place an identification label only in the label slot on the front of the
tape cartridge.
Store tape cartridges in a dust-free environment.
Keep tape cartridges away from direct sunlight, heaters, and other
sources of heat. Store tape cartridges in a stable temperature between
10° and 40°C (50° and 104°F).
Store tape cartridges where the relative humidity is between 20 and 80
percent.
Keep tape cartridges away from magnets and equipment that generate
magnetic fields, such as motors, transformers, terminals, and audio
equipment.
Keep tape cartridges away from x-ray equipment.

3.1.2.4 Inserting a Tape Cartridge

Before you use the tape drive, make sure the system is turned on. During
power-up, the TF85 drive runs self-tests that last a few seconds.
four indicator lights come on momentarily, then the yellow (Tape in Use)
indicator blinks during the self-tests. At the end of the tests, the yellow
indicator goes off and the green (Operate Handle) indicator comes on,
accompanied by a short beep. The green indicator and the beep indicate
that you can move the cartridge release handle.
CAUTION: Move the handle only when the green indicator light is on.
Moving the handle while the yellow indicator light is on could damage the
drive. If all four indicators blink rapidly at any time, a fault condition exists.
Press the Unload button once. If the fault is cleared, the tape unloads. The
yellow indicator blinks during unloading, then the green indicator comes
on. If the fault is not cleared, the four indicators continue to flash. Do not
3–12 VAX 4000 Model 200 (BA430) Operation