COOL Mode: thermostat controls the temperature according to the following
diagram
Output
Set point
Turn off
Turn on
Off
Swing
o
Example for Cooling: (Set point = 80 F, Swing = 1 F)
o
=> Cooler turns on when room temp is 81 F and off at 79 F.
AUTO:
thermostat controls the temperature according to the following
diagram
Output
Heat Set point
nd
nd
2 Turn on
2 Turn off
st
st
1 Turn on
1 Turn off
Off
Diff
Swing
Dead band
o
o
There is a dead band 4 F/2 C between heat set point and cool set point.
o
Example 1: If user select heat set point is 70 F, the minimum cool set point will be
o
limited at "heat set point" + 4 F: 74 F
o
Pervious heat set point is 70 F and cool set point is 74 F
Example 2: If user changes heat set point to 72 F, cool set point will be updated to
o
76 F automatically to maintain the dead band.
15

Change Mode

Note: In Heat mode
Below example is based on HEAT PUMP
Step
Cool
Temperature
o
o
Cool Set point
Heat
Temperature
Swing
o
o
o
=>it displays "HEAT" if ELECTH is selected during jumper
setting.
=> it displays "HEAT PUMP" if HPUMP is selected during
jumper setting.
Procedure / Description
Press "Mode" key once to change the
operation mode:
1
OFF -> HEAT (PUMP) -> COOL -> AUTO
-> OFF
16
LCD indication
MO
WAKE
AM
OFF
FAN AUTO
MO
WAKE
AM
HEAT
FAN AUTO
MO
WAKE
AM
COOL
FAN AUTO
MO
WAKE
AM
AUTO
FAN AUTO