EPSON Stylus Photo 1390/1400/1410
Hook both rear ends of the Paper EJ Frame Assy onto the tabs
of the Main Frame.
Align the Bearing of the CD-R Release Level Sub Assy with the
Paper EJ Release Shaft.
Shaft and
Bushing
Figure 4-87. Installing the Paper EJ Frame Assy
Match the tabs with the five Positioning Holes.
Tighten the screws in the order shown in
After replacing or removing the Paper EJ Frame Assy, the
A D J U S T M E N T
R E Q U I R E D
following adjustment must be performed.
1. PW Sensor Adjustment
2. PF Adjustment
3. PF Adjustment (Bottom Margin)
Refer to Chapter 5 "Adjustment" for details on the adjustments.
DISASSEMBLY AND ASSEMBLY
Shaft and
Bushing
Tabs
See Figure 4-85.
Figure 4-86.
(p.133)
(p.133)
(p.133)
Disassembly/Assembly Procedures
4.2.6.8 CD-R Release Lever Sub Assy
The Stylus Photo 1390 does not have the CD-R Release Lever Sub
C H E C K
P O I N T
Assy. Skip this section for the model.
1.
Remove the Paper EJ Frame Assy.
2.
Remove the Shaft on the Right CD-R Release Base from the Bushing on the CD-R
Release Lever.
Right CD-R Release Base
Figure 4-88. Removing the Right CD-R Release Lever Sub Assy (1)
Revision B
See section 4.2.6.7 on page 106.
Shaft and Bushing
CD-R Release Lever
107