Testing & Commissioning - Rinnai FS35 ETR Accessory Installation Manual

Electronic timer and remote operating and installation instructions
Hide thumbs Also See for FS35 ETR:
Table of Contents

Advertisement

TESTING & COMMISSIONING
Comple
TESTING PROCEDURE
Turn gas supply on and plug the unit into the power supply. (Caution 240V.)
TO CHECK BURNER PRESSURE
• Refer to Data Plate.
• Remove the wiring cover panel.
• Remove test point screw and attach manometer to test point.
The test point is on the front side of the gas valve.
• Light heater, turn to High heat setting and
check pressure.
• If adjustments are necessary, the regulator is situated on
the front of the gas control.
• After checking pressure, turn the unit off, remove manometer and replace test point screw.
• Turn the heater on and off a few times to check ignition.
• When you are satisfied that the heater is working correctly, reassemble panels.
• All burner aeration is factory preset and cannot be adjusted.
• If you are unable to get the unit to operate correctly, refer to Troubleshooting on Page 9,
before contacting your local service contact as listed on Page 14.
• It may take approximately 2 hours for the logs to achieve their full flame pattern and glow.
During the initial burning in period, some smoke and smell may be experienced. The
heater should be run on the high position in a well ventilated room until these dissipate.
It is the responsibility of the installer to check that under normal operating conditions of the
appliance, all flue gases are exhausted to the outside atmosphere and that there is no spillage
of combustion gases into the room. Please refer to AS5601 / AG601 clauses 5.13.3.3
COMMISSIONING
INSTALLATION AND COMMISSIONING CHECKLIST
Complete the installation / commissioning checklist and the installer / gasfitter details on page 12 and
make sure that this instruction book is left with the customer.
INSTRUCT CUSTOMER ON USE OF UNIT
Explain to customer about use and care of unit. Make sure the customer understands the instructions.
EXPLAIN TO THE CUSTOMER
Ignition, Adjusting heat level, Fan Switch, Turning "OFF".
The guard on this appliance conforms to AGA. requirements. It is designed to prevent the risk of
fire or injury from burns, and no part of it should be permanently removed.
IT DOES NOT GIVE FULL PROTECTION TO YOUNG CHILDREN OR THE INFIRM.
NOTE:
RINNAI RESERVES THE RIGHT TO CHANGE OR MODIFY SPECIFICATIONS WITHOUT NOTICE.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timberflame fs35 etrFreestanding royale etr

Table of Contents