Service Procedures; Removal From Joinery Cavity; Components In Control Panel Area - Fisher & Paykel Titan AeroTech OD302-B Service Manual

302b series titan oven
Table of Contents

Advertisement

Service Manual 599337A: 302B Series Titan Oven

7. Service Procedures

In order to service components of the oven, certain procedures must be followed. These
procedures are as follows:
To avoid stripping screws do not over tighten when reassembling parts. If using a
screw gun have the torque setting on low.
Take extra care not to damage wire terminals on removal as some have release clips.

7.1 Removal from Joinery Cavity

1. Disconnect the unit from the power supply.
2. Remove the oven doors, shelves and utensils. (refer to Section 7.21)
3. Remove the two screws on either side of the oven frame that secure the oven to the
joinery.
4. Slide the oven out of the cavity onto a suitable support.
Warning!
This oven is heavy and care should be taken to use correct lifting
techniques.
Reassembly
Refit in reverse manner

7.2 Components in Control Panel Area

1. Remove the oven from the joinery cavity. (refer to Section 7.1)
Warning! To avoid the oven tipping forward, remove the shelves, utensils and doors.
(Refer to Section 7.21)
Note: The oven does not need to be removed completely from the joinery cavity. Sliding
the oven out eight inches (200mm) will give sufficient access space.
2. Detach the control panel from the frame uprights by removing the two screws located
either side of the rear of control panel.
3. Remove the wiring harness from the power module.
4. Lift the control panel off the two support brackets.
The function, temperature and clock modules are now accessible.
Reassembly
Refit in reverse manner.
45
July 2006

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Titan aerotech os302-b

Table of Contents