4. Connect a USB cable (DT-380USB) to the USB client port on the back of the cradle, and then
connect the other end of the cable to the PC. USB host port is used when connecting the cradle with
other USB peripheral device.
Figure 4.4
5. Align the USB cradle mount holes on the back of the DT-X7 with the mount hooks on the cradle after
aligning the contacts on the bottom of the DT-X7 with the power contacts of the cradle. The power
LED on the front of the cradle will light green if the DT-X7 has been properly mounted.
Figure 4.5
Status of Indicator 1 on DT-X7
Orange
: Charging the battery pack.
Red
: Standby due to battery pack error or the surrounding temperature is out of the range (charging
begins when the temperature returns within the correct range.)
Green
: Charging the battery pack is complete.

Important notes:

• Always remove the DT-X7 from the cradle when switching the selector switch on the cradle.
• Never short the power contacts of the cradle. This damages the cradle.
• Do not subject the DT-X7 and cradle to vibration or impact during communication. This results in
communication being interrupted.
• When mounting the DT-X7, securely attach it to the mount hooks of the cradle and check that the
power LED on the front of the cradle lights green. Charging the battery pack or communication will
not proceed if it is not mounted properly.