NOTE: You will need to use a gas rated
sealer on gas connectors that are not flared.

Plumbing for Side Burners

1.
Assemble a 3/8" pipe nipple to the
3/8" pipe tee using Teflon tape or
pipe sealant. Use only sealant that is
approved for use on LP gas.
2.
Install the pipe tee assembly to the
GAS LINE
grill intake pipe. Tighten assembly
and align the branch opening of the
tee with the hole of the cabinet.
3.
Connect the flexible hose (male end)
to the pipe tee.
4.
Install the side burner into the island
by simply setting it in place.
5.
Connect the female end of the flex-
ible hose to the side burner intake
pipe.
6.
Connect gas supply to the grill.
7.
Check for gas leaks using soap water
solution.

Electrical Supply Requirements

Your Cal Flame grill must be plugged into a perma-
nent, grounded 110V outlet with a dedicated 15A
GFCI breaker in accordance with local codes or the
National Electrical Code, ANSI / NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
It is the owner's responsibility to ensure that the
electrical connection to this appliance is properly
installed. We recommend a contractor or licensed
electrician install a dedicated 110V electrical service
for your grill.
Do not use an extension cord to supply power to
your Cal Flame grill. Such use may result in fire, elec-
trical shock or other personal injury.
Barbecue Grills
LTR50001038, Rev. B
the back of the grill. (Use gas rated tape seal on all
connections).
Connect the last open line to the side burner
C
(Use gas rated tape seal on all connections)
Items Included with Barbecue
1) "T" adapter, 3/8"
2) 2 hose fittings, 3/8"
3) Regulator with hose
"T" adapter, 3/8" Threaded
To grill, located
underneath and
behind grill
From Grill
3/8" Fittings
NOTE: You will need to use a gas rated
sealer on gas connectors that are not flared.
Do not install a fuse in the neutral or ground circuit.
A fuse in the neutral or ground circuit may result in
an electrical shock hazard.
Do not ground this appliance to a gas supply pipe or
hot water pipe.
Use copper wire only. The use of aluminum wire may
result in unsatisfactory connections.
Install 120VAC, 15 Amp duplex outlet in an acces-
sible location under the grill inside the base enclo-
GAS LINE
sure.
Locate the electrical supply box inside the built-in
enclosure within reach of the power cord so the con-
nection is accessible when the grill is completely in-
stalled in the enclosure.
GAS LINE
To side burner, located
underneath behind burner.
From Side Burner
To Propane Tank
www.calflamebbq.com
7
Open
A
tank. T
use ga
proper
Gr
Then t
B
and co
the ba
conne
Conne
C
(Use g

Advertisement