Gas Connection; Leak Testing Procedure - Cal Flame BBQ08873P Owner's Manual

3/4/5 burner grill
Hide thumbs Also See for BBQ08873P:
Table of Contents

Advertisement

10

Gas Connection

Gas Requirements and Connection
IMPORTANT: The Cal Flame grill is manufactured to operate on liquid propane (LP). However, it can be
converted to operate on natural gas (NG) by an authorized service technician. Consult your Cal Flame dealer
for information on converting your gas grill.
Owners must not convert their grills themselves . Attempting to convert the grill from LP to NG
may result in serious injury and will void the warranty coverage .
If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at
your local hardware store. Without it you will not be able to attach your tank to your Cal Flame™ grill or
refill the tank at your local propane refill station.

Leak Testing Procedure

Perform a leak test at least once a year whether the
gas supply cylinder has been disconnected or not.
In addition, whenever the gas cylinder is connected
to the regulator or whenever any part of the gas
system is disconnected or replaced, perform a leak
test.
As a safety precaution, remember to always leak test
your grill outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while
doing a leak test. Do not use a flame, such as a
lighted match to test for leaks. Use a solution of
soapy water.
1.
Prepare a leak testing solution of soapy water by
mixing in a spray bottle one part liquid soap to
one part water.
2.
Make sure all the control knobs are in the OFF
position.
3.
Turn on the gas.
a.
On
natural gas systems, turn the main feed
valve to the grill.
b.
On
LP systems, turn the cylinder valve knob
counter clockwise one turn to open.
www.calflamebbq.com
4.
Apply the leak-testing solution by spraying it on
joints of the gas delivery system. Blowing bub-
bles in the soap solution indicates that a leak is
present.
5.
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement part
recommended by the manufacturer. Do not at-
tempt to repair the cylinder valve if it is dam-
aged. The cylinder must be replaced.
6.
Turn all control knobs back to the full OFF posi-
tion.
If you are unable to stop a leak:
1.
Turn all control knobs back to the full OFF posi-
tion.
2.
Shut off the gas supply to the grill and release
pressure in the hose and manifold by pushing in
and turning any of the control valves one quar-
ter turn counter-clockwise.
3.
On LP systems, remove the cylinder from the
grill.
4.
Call an authorized gas appliance service techni-
cian or an LP gas dealer.
Do not use the appliance until the leak is corrected.
Barbecue Grills
LTR50001038, Rev. B

Advertisement

Table of Contents
loading

Table of Contents