Sync Input Conditions - Barco HDM 5049 PLUS User Manual

High definition monitor
Table of Contents

Advertisement

HDM 5049 PLUS

3.3.3 Sync Input Conditions

GREEN
HS / CS
VS
SOG
CS
HS
VS
+
+
1
+
2
+
/
3
+
4
5
/
6
/
+
7
/
8
/
/
9
+
+
10
+
11
+
/
12
+
13
14
/
15
/
+
16
+
/
+
17
/
+
/
18
/
+
19
/
20
/
/
21
/
/
+
22
/
/
23
/
/
/
24
/
+
+
25
/
+
26
/
+
27
/
/
+
28
/
29
/
/
30
+: Positive Sync
HDM5049 P
Picture
LUS
Clamping problem
No vertical sync due to addition of
two opposite pulses
Clamping problem
Clamping problem
OK
No vertical sync due to addition of
two opposite pulses
OK
OK
No vertical sync due to addition of
two opposite pulses
OK
Clamping problem
No vertical sync due to addition of
two opposite pulses
Clamping problem
No vertical sync due to CS/HS
priority on SOG
Clamping problem
OK
OK
No vertical sync due to CS/HS
priority on SOG
OK
No vertical sync due to addition of
two opposite pulses
OK
OK
No vertical sync due to addition of
two opposite pulses
OK
No horizontal sync
No horizontal sync
No Sync
OK
OK
No vertical sync
OK
OK
No vertical sync
: Negative Sync
HDM 5049 PLUS Installation
Remove CS (⇒ condition 7) or
remove SOG (⇒ condition 16)
Remove VS to solve Vert Sync problem and
Remove CS to solve Clamping problem
(⇒ condition 9) or
Remove VS to solve Vert Sync problem and
remove SOG (⇒ condition 18)
Remove CS (⇒ condition 9 ) or
Remove SOG (⇒ condition 18)
Remove VS to solve Vert Sync problem
(⇒ condition 6)
Remove VS (⇒ condition 9)
Remove HS (⇒ condition 7)
Remove VS to solve Vert Sync problem and
Remove HS because no vertical sync is present
any more (enable SOG, ⇒ condition 9) or
remove SOG (⇒ condition 26)
Remove HS (enable SOG, ⇒ condition 9)
Remove HS (enable SOG, ⇒ condition 9)
Remove VS (⇒ condition 18)
Remove VS (⇒ condition 21)
⇒ Valid condition
⇒ Valid condition
⇒ Valid condition
⇒ Valid condition
⇒ Valid condition
/: Not connected
Solution
Page 3-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents