Barco HDM 5049 PLUS User Manual page 18

High definition monitor
Table of Contents

Advertisement

Operation And Adjustment
Automatic
Remember that the monitor will be aligned according to the Color temp. and White level settings
you have made in the Settings menu. If you align the monitor to 6000 K and 80 nit, you can set it to
6500 K and 90 nit in the Settings menu, but then, the color temperature and light output will be
approximate. To obtain 6500 K and 90 nit, make sure you make the correct settings before starting
automatic alignment.
The HDM 5049 PLUS can be automatically aligned with a Thoma TMF3 or TMF 6 Color Analyzer
or with a Philips® PM5639/90 Color Sensor.
Required for alignment with Thoma TMF3 or TMF6:
Thoma TMF3 or TMF6 Color Analyzer
ThomaLink connector cable, order number Z345501.
Required for alignment with Philips® PM 5639/90 Color Sensor
HDM 5049 PLUS Software version 1.03 or higher (see Information Menu on page 4-10)
Philips® PM 5639/90 Color Sensor
Power Supply box for PM 5639/90 Color Sensor
Power cord
Interface cable between monitor and Power Supply box (male and female SubD-9 connectors)
Interface cable between Color Sensor and Power Supply box (FCC68 connectors)
All required items are included in the Philips® PM 5639/01 kit or the combined PM 5639/02 and PM
5639/62 kits.
To align the HDM 5049 PLUS, proceed as follows:
With Thoma Color Analyzer:
1. Connect the Thoma TMF3 or TMF6 Color Analyzer to the Service connector on the rear of the
monitor using a ThomaLink connector cable (order number Z345501).
2. Cover the Thoma sensor and press [ADJ] twice. This will start the zero calibration. Then press
[XYZ]. The Thoma should now read values between -4 and +4.
3. Connect the grounding clip on the Thoma sensor to one of the monitor's handles before
placing the sensor on the screen. This prevents damage to the Thoma in case the monitor
flashes.
With Philips® PM 5639 Color Sensor:
1. Connect the Color Sensor to the Power Supply box via the interface cable with FCC68
connectors.
2. Connect the HDM 5049 PLUS Service connector (on the rear) to the RS232-C IN connector on
the Power Supply box using the interface cable with the male and female SubD-9 connectors.
3. Apply power to the Power Supply box.
For Thoma and Philips® :
1. Connect a 100% White Field to the monitor.
2. Place the sensor in the center of the screen. Do not turn on or off the monitor while the sensor
is on the screen!
3. With
or
If the monitor does not recognize the Thoma Color Analyzer or the Philips® Color Sensor, following
message is displayed after a while:
Page 4-6
select Automatic in the Color menu and press
HDM 5049 PLUS
to start the alignment.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents