Bypassing Zones; Reviewing The Bypassed Zone List - Visonic PowerMaxComplete User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaxComplete:
Table of Contents

Advertisement

USER SETTINGS

Bypassing Zones

A. General Guidance
You can program the PowerMaxComplete to exclude
(bypass) selected zones, regardless of whether
these zones are "functional" (undisturbed) or "open"
(disturbed). Bypassing permits free movement of
people within certain zones although the system is
armed. It is also used to temporarily remove from
service faulty zones that require repair work. Fire
zones can not be bypassed.
Remember – zone bypassing compromises security!
Zone bypassing must be carried out while the system
is in the disarmed state.
Note: Zones will be bypassed throughout one
disarm-arm period only. Disarming the system after
arming will suspend the entire bypassing scheme,
which can be recalled later, if so desired.
B. Bypassing Procedure
Having entered your user code successfully (see
above - Entering to the User Settings Menu), the
display will read:
SET BYPASS
If at this point you click
state and name of the first zone will be automatically
displayed. Three states are possible:
Open: The zone is not secured - you can
bypass it if you do not wish or know how to solve
the problem just now.
Bypassed: The zone is presently bypassed
(you bypassed it before but haven't armed the
system yet).
Functional: If there is nothing wrong with the
zone, its state is described as "Functional".
Let us assume that Zone 1 is "open" and you wish to
bypass it, and the rest of the zones are functional.
PRESS
RESULTANT DISPLAY
Z01: OPEN
(alternating)
KITCHEN
<OK> TO BYPASS
Z01: BYPASSED
(alternating)
KITCHEN
Z02: FUNCTIONAL
(If you wish
(alternating)
to check the
FRONT DOOR
state of the
next zone)
SET BYPASS
22
You can select any other item on the USER SETTINGS
menu or quit programming by clicking
<OK> TO EXIT is displayed - click
After end of bypassing operation, BYPASS blinks:
READY BYPASS
This indication will persist as long as the system
remains disarmed, and will disappear once the
system is armed.
Note: BYPASS will alternate in the display with other
messages, like: Trouble, Memory and Message.
C. "Unbypass" Procedure
Suppose you wish to restore a zone to service after
having completed the bypassing scheme. Simply re-
enter the SET BYPASS menu (see Bypassing
Procedure above), and click
the zone you wish to "unbypass" is on display. Refer
to the following steps.
PRESS
, the number,
You may now click
item on the USER SETTINGS menu, or click
to quit programming. When <OK> TO EXIT appears
- click

Reviewing the Bypassed Zone List

Having entered your user code successfully (see
above - Entering to the User Settings Menu), the
display will read:
Click
Click
If at this point you click
state and name of the first bypassed zone will be
displayed.
You can now click
all bypassed zones, in ascending numerical order.
When done, clicking
SHOW BYPASS and clicking
to <OK> TO EXIT.
or
NOT READY BYPASS
or
RESULTANT DISPLAY
Z22: BYPASSED
(alternating)
LIVING ROOM
<OFF> TO CLEAR
Z22: FUNCTIONAL
(alternating)
LIVING ROOM
and then select any other
.
SET BYPASS
to change the display into:
SHOW BYPASS
to change the display into:
BYPASS LIST
, the number,
repeatedly to review
will get you back to
will get you back
. When
.
until
D-300886

Advertisement

Table of Contents
loading

Table of Contents