Chapter 3. Operation; Initial Setup (Single-Thread System) - Comtech EF Data KST-2000B Installation And Operation Manual

Ku-band satellite transceiver
Table of Contents

Advertisement

This chapter provides the following information: Initial setup (single-thread system),
initial setup (redundant system), RJU-2000 Redundant Junction Unit description, 1:1 re-
dundant KST-2000A/B system operation, Up converter description, and Down converter
description.
3.1

Initial Setup (Single-Thread System)

This section details the procedures necessary to laboratory test a single-thread
KST-2000A/B system for the first time. Refer to Figure 3-1 for system setup.
Note: Ensure that the termination selected for the HPA output is sized to handle the
1.
2.
3.

Chapter 3. OPERATION

HPA output power.
Apply power to the KST-2000A/B.
After a few seconds ensure that the GREEN TX ON LED is flashing, and the
fault LED is extinguished. Refer to Section 4 if this is not the case.
Using a KP-10 or PC equipped with a terminal or Windows™ based M&C pro-
gram, ensure communication is available to the system M&C, via J2, remote
connector. (Refer to M&C software manual, P/N MN/M&CWIN.IOM)
Default Communication Parameters
Address
Baud Rate
Parity
Stop bits
Data length
3–1
1
9600
Even
2
7 bits