Ku-Band Satellite Transceiver
FSK Remote Control Commands
Parameter
Command
Type
(Instruction
Code and
qualifier)
Concise LNA
n.a.
Settings
HPA Power
AMP=
Enable
HPA Fault
KFE=
Enable
Arguments for
Description of arguments
Command or
(note that all arguments are ASCII numeric codes, that is, ASCII
Response to
codes between 48 and 57)
Query
<add/LFL?'cr'
>add/LFL=x'cr''lf'
Where: x = 0 (Fault reporting disabled)
1 (Fault reporting enabled)
2 bytes
Query only.
<add/CLS?'cr'
>add/CLS=nx'cr''lf'
Where:
n = Power Enable; 0 (Off), 1(On)
x = Fault Enable; 0 (Disabled), 1 (Enabled)
1 byte
Command or Query.
<add/AMP=x'cr'
>add/AMP='cr''lf'
<add/AMP?'cr'
>add/AMP=x'cr''lf'
Where: x=0(Off) or 1(On) Default is 1 (On)
Note: For EF Data SSPA only, which turns ON/OFF DC voltage
supplied to HPA.
1 byte
Command or Query.
<add/KFE=x'cr'
>add/KFE='cr''lf'
<add/KFE?'cr'
>add/KFE=x'cr''lf'
Where: x=0 fault reporting disabled
y=1 fault reporting enabled
Response to Command (target to
controller)
LFL* (message ok, but not permitted in
current mode)
CLS= (message ok)
CLS? (received ok, but invalid argument
found)
CLS* (message ok, but not permitted in
current mode)
AMP= (message ok)
AMP? (received ok,
but invalid arguments found)
AMP* (message ok, but not permitted in
current mode)
KFE= (message ok)
KFE? (received ok,
but invalid arguments found)
KFE* (message ok, but not permitted in
current mode)
E-9
Revision 9
MN/KST2000AB.IOM
Query
(Instruction
Code and
qualifier)
CLS?
AMP?
KFE?
Need help?
Do you have a question about the KST-2000B and is the answer not in the manual?