7.12.2 Replacing other electronic components

CLAM (1) (only installed if the wheelchair is
equipped with electric adjustment options)
• Disconnect the plug-in connections of all
cables on the CLAM.
• Push CLAM forwards and remove.
Servo-Light-Module (2)
• Disconnect the plug-in connections of all
cables on the Servo-Light-Module.
• Loosen and remove the screws of the fixation
bracket using a cross-tip screwdriver.
• Remove Servo-Light-Module.
• Re-assembly of the electronic components is carried out in the reverse order.
• Check all vehicle functions.