Invacare G50 Service Instructions Manual page 24

Wheelchair
Hide thumbs Also See for G50:
Table of Contents

Advertisement

SERVICE INSTRUCTIONS
Remote status bar
indicator LED blink
code
6
7
8
9
10
11
24
Servo light
module LED
blink code
Magnetic brake defective or
-
drive disengaged
Battery voltage too low
-
Battery voltage too low (below
7
17V)
Battery voltage too high
-
CANL error
CANL error problems on the
9
CANL channel /
communication over CANL not
possible.
CANH error
-
CANH error problems on the
10
CANH channel /
communication over CANH
not possible.
Maximum current time-out
-
(drive overloaded or
overheated)
Cause
®
Invacare
- G50
Fault remedy
Engage motor. Switch the
electronics system off and
on again.
Check the connecting
plug
Replace motor See
"Replacing a motor" on
page 41
Charge battery. See User'
Manual
Check battery
connections
Check fuses.
Check batteries and
replace if necessary. See
User' Manual
Turn on lighting
Check bus cable/data
cable for short circuit. An
open circuit or a short
circuit in one of the ACS-
Modules can also cause
this error. See "Checking
the cables" on page 87
and "Replacing
electronics
components" on page 77
Check bus cable for
continuity
Check bus cable/data
cable for short circuit. An
open circuit or a short
circuit in one of the ACS-
Modules can also cause
this error. See "Checking
the cables" on page 87
and "Replacing
electronics
components" on page 77
Check bus cable for
continuity
Switch the electronics
system off and on again.

Advertisement

Table of Contents
loading

Table of Contents