Honeywell MS9540 Manual page 31

Honeywell ms9540 barcode scanner manual
Hide thumbs Also See for MS9540:
Table of Contents

Advertisement

Supported by the MS9500 series only.
The following example demonstrates how to configure the User-Defined ISBT
identifiers:
Assume the left-hand identifiers are the ISBT defined donation identification
number: "=G"; and the right hand identifiers are country specific identifiers "&a".
1.
Scan the ENTER/EXIT configuration mode bar code.
2.
Scan the 1
3.
Scan (Code Byte 0) + (Code Byte 6) + (Code Byte 1).
4.
Scan the 2
5.
Scan (Code Byte 0) + (Code Byte 7) + (Code Byte 1).
6.
Scan the 1
7.
Scan (Code Byte 0) + (Code Byte 3) + (Code Byte 8).
8.
Scan the 2
9.
Scan (Code Byte 0) + (Code Byte 9) + (Code Byte 7).
10. Scan the Enable User-Defined Sequence bar Code.
11. Scan the Enable ISBT bar code.
12. Scan the ENTER/EXIT configuration mode bar code.
The scanner is now configured with the appropriate identifiers. Since both ISBT
and User-defined Concatenation are enabled, ISBT 128 bar codes scanned
successively that contain these identifiers will be concatenated.
An alternate method of the type found in section 4.8.1 of the ISBT specifications
can be used for configuring user-defined concatenation sequences. Using the
previous example, the identifiers can be configured into a single configuration
mode bar code. The following bar codes can be used to enable and disable the
user-defined concatenation.
These configuration-mode bar codes differ from Metrologic's normal set of
configuration mode bar codes and can only be used in single-code configuration
mode. In Multi-Code configuration mode, these bar codes are not recognized.
Two forms of concatenation can be enabled at any given time - one pre-defined
sequence and the User-defined sequence. Code selects and ISBT Code-128
concatenation cannot be used simultaneously. Both functions use the same
internal resources so they must remain mutually exclusive.
24
ISBT C
128 I
ODE
st
Left Identifier configuration mode bar code.
nd
Left Identifier configuration mode bar code.
st
Right Identifier configuration mode bar code.
nd
Right Identifier configuration mode bar code.
Enable (Left, =G) + (Right, &a)
=
&
³
=
Disable (Left, =G) + (Right, &a)
=
&
³
=
MPLEMENTATION
G
&
a
5
0
G
&
a
5
0
5
d
1
5
d
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms9544

Table of Contents