Chapter 1: Overview
Power Supplies
34
The x510 Series switches have two AC power supplies with separate AC
connectors on the back panels. The power supplies, which are not field-
replaceable, provide a switch with power redundancy and protect against
interruptions to network operations in the event one of the power supplies
loses power or fails. Power redundancy is available only when both AC
connectors on a switch are connected to power sources.
Refer to "Technical Specifications" on page 103 for the input voltage
range.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Warning
This unit might have more than one power cord. To reduce the risk
of electric shock, disconnect all power cords before servicing the
unit. E30
Note
The switches are powered on or off by connecting or disconnecting
the power cords.