Finalizing the Installation
5
Attach the rear log bracket to the burner as shown below (use the two included screws).
6
Place the included rivet into the far right burner hole as shown below.
7
Replace the firebox components. Install the logs and embers. Replace the glass.
8
Replace the regulator following the instructions included with the regulator kit. Remove and discard
the screws (see "a" below) holding the stock regulator in place (see "b" below). Remove the stock
regulator and gasket (see "c" below). Place the LP regulator in place, making sure the pre-fitted
gasket (see"c" below) is in place.
9
Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line
(if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.