Special Installation (Embedding in the wall)

3.4.3 Embedding in the wall

Carefully read the following before trying to embed the unit in a wall, and make sure to observe all the limitations
specified below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (With no obstructions within a distance of 300 mm
from the back surface of the unit).
A
A
✩ Operating Temperature Restrictions
* The same operating temperature restrictions apply to the speaker system (PDP-S44-LR).
✩ Operating Temperature Restrictions for Upside-Down Installations
* Upside-down mounting is unavailable when embedding this device in a wall.
A
<Viewed from the Right Side>
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
Before attaching the unit to fittings, double-check that the thickness and height of the fittings,
and the number of fixing bolts is correct.
(Also refer to "3.4.1 Mounting to fittings (pg. 28)".)
32
X (Front of the unit)
Y (Rear of the unit)
<Viewed from Above>
Temperature in space X and Y
A: 0 mm to 370 mm
. The methods indicated by a large X-mark must not be used.
A
0 °C to 40 °C