Special Installation; Mounting To Fittings - Pioneer PDP-425CMX Technical Manual

For pioneer plasma display monitor when used with video cards (expansion solutions cards)
Hide thumbs Also See for PDP-425CMX:
Table of Contents

Advertisement

Special Installation (Mounting to fittings)

3.4 Special Installation

The unit can be hung from or embedded in a wall, but such special installations impose additional limitations on
operating temperatures and other operational factors.
Examine installation methods and the ambient conditions for your installation site, and refer to sections "3.1 Installation
Site Requirements (pg. 18)", "3.2 Installation Conditions (pg. 20)", "3.3 Installation Procedures (pg. 24)" in this manual.
Measurements discussed in this manual assume the following conditions:
• A 100 % white input is supplied.
• Sufficient aging has been completed.
Make all measurements under identical conditions. The aging period required for correct
measurement will be about two and a half hours, depending on the space available at the
installation site.

3.4.1 Mounting to fittings

Observe the following guidelines when mounting the unit to fittings.
Notes 2 to 8 apply to all cases of mounting to fitting.
1 When mounting the unit, make sure that there are no objects around it within a distance of 300mm.
2 Any unit deformation/warping occurring as a result of installation should be less than 4 mm.
3 Never block or cover openings, aside from those shown as blocked in the illustrations on the following page.
4 The fittings should have a thickness of less than 20 mm. (This limit does not apply to fittings in examples 1, 3, 5
and 6 on the following page.)
5 L-shaped fittings should have a thickness of less than 100 mm.
6 The strength of the fittings should be adequate to bear the weight of the display.
7 Take precautions to avoid sharply bending the power cable.
8 If necessary it is possible to remove the handles. When reinstalling the handles, be sure to completely tighten the
screws to ensure safety.
Maximum allowable deformation/warping is 4 mm.
Arrange the power
cable so that minimum
stress is placed on it.
✩ Operating environment for standard installation
• Ambient Temperature: 0 °C to 40 °C (examples 1 to 3)
✩ Operating environment for vertical installation
• Ambient Temperature: 0 °C to 40 °C (vertical installation: examples 4 to 6)
✩ Operating temperatures for Upside-Down Installations (examples 1 to 3)
• Ambient Temperature: 0 °C to 40 °C
The operating temperature restrictions for the speaker system (PDP-S44-LR) are the same regardless of whether
installation is horizontal or vertical.
Note
When a video card other than PDA-5003/PDA-5004 is used, the operating temperature conditions given above cannot
be assured. Check the video card operating instructions for the conditions.
28
Less than
20 mm
(No thickness limitations in examples 2
and 4 on the following page.)
Less than
100 mm
Less than
20 mm
(No thickness limitations in examples 2
and 4 on the following page.)
L-shaped fitting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-42mxe10

Table of Contents