845.00 Front scan module cable failure or SCC card failure CCD channel failure
Step
Action and questions
1
Check flatbed CCD cable (A).
1. Remove the flatbed glass. See
glass removal" on page 4-28
2. Remove the bottom plate to expose the cable.
See"Bottom plate removal" on page 4-35
information.
Is the cable loose?
2
Is flatbed CCD cable broken?
845.01 Rear scan module cable failure or SCC card failure CCD channel failure
Step
Action and questions
1
Check ADF/CCD data cable (A).
Is the cable loose?
2
Is ADF/CCD data cable broken?
"Flatbed cover with
for more information.
for more
4036-307, -308
Yes
No
Reseat flatbed
Go to step 2
CCD cable
Replace flatbed
Replace
CCD cable
scanner control
board
Yes
No
Reseat ADF/
Go to step 2
CCD data cable
Replace ADF/
Replace
CCD data cable
scanner control
board
Diagnostic information
2-19