4036-307/308
844.01 Rear scan module output level error
Step
Action and questions
1
Check the ADF lamp.
Is the lamp on brightly?
2
Is the SDF lamp on dimly?
844.02 Front scan module lamp level too low
Step
Action and questions
1
Check the flatbed lamp.
Is the lamp on brightly?
2
Is the flatbed lamp on dimly?
3
Is the flatbed CCD cable securely
connected?
845.00 Front scan module cable failure or SCC card failure CCD channel failure
Step
Action and questions
1
Check flatbed CCD cable.
Is the cable loose?
2
Is flatbed CCD cable broken?
845.01 Rear scan module cable failure or SCC card failure CCD channel failure
Step
Action and questions
1
Check ADF/CCD data cable.
Is the cable loose?
2
Is ADF/CCD data cable broken?
845.02 Cable/SCC failure
Step
Action and questions
1
Is the flatbed CCD data cable securely attached?
2-16
Service Manual
Yes
Go to step 3
Replace flatbed optical
unit
Yes
Go to step 3
Replace flatbed inverter
board
Replace flatbed optical
unit
Yes
Reseat flatbed CCD cable
Replace flatbed CCD cable
Yes
Reseat ADF/CCD data cable
Replace ADF/CCD data
cable
Yes
Replace the flatbed
CCD data cable
No
Go to step 2
Replace flatbed lamp
No
Go to step 2
Replace flatbed lamp
Reseat flatbed CCD
cable
No
Go to step 2
Replace scanner control
board
No
Go to step 2
Replace scanner control
board
No
Reseat flatbed CCD
data cable