Rated Voltage
Rated Maximum Load Current (Amps) at 240 Volts (LP)*
Main Circuit Breaker
Transfer Switch Load Center Circuits** 30A, 240V
30A, 240V
20A, 120V
15A, 120V
Phase
Number of Rotor Poles
Rated AC Frequency
Battery Requirement
Weight (unit only in lbs.)
Enclosure
Normal Operating Range: This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 °F (-29 °C) to 122 °F. (50 °C). For areas
where temperatures fall below 32 °F (0 °C), a cold weather kit is highly recommended. When operated above 77º F (25º C) there may be a decrease in engine
power. (Please reference the engine specifications section).
These generators are rated in accordance with UL2200, Safety Standard for Stationary Engine Generator Assemblies; and CSA-C22.2 No. 100-04 Standard for
Motors and Generators.
* Natural Gas ratings will depend on specific fuel Btu content. Typical derates are between 10-20% off the LP gas rating.
** Circuits to be moved must be protected by same size breaker. For example, a 15 amp circuit in the main panel must be a 15 amp circuit in the transfer switch.
Type of Engine
Number of Cylinders
Rated Horsepower @ 3,600 rpm*
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Recommended Spark Plug
Spark Plug Gap
Compression Ratio
Starter
Oil Capacity Including Filter
Recommended Oil Filter
Recommended Air Filter
Operating RPM
* Engine power is subject to and limited by such factors as fuel Btu content, ambient temperature and altitude. Engine power decreases about 3.5 percent for each
1,000 feet above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F) ambient temperature.
Page 4

GENERATOR

240
29.2
30 Amp
1
1
3
3
1
2
60 Hz
Group 26R, 12 Volts and 525 CCA Minimum
225
Composite

ENGINE

OHV-432
1
14.8
432cc
Aluminum w/Cast Iron Sleeve
Overhead Valves
Solid-state w/Magneto
RC12YC
0.76 mm (0.030 inch)
8.2:1
12 VDC
Approx. 1.1 Qts (1.0L)
Part # 0H9039
Part # 0H6104
3,600