Generac Portable Products 5500XL Generator
GENERAL
MAINTENANCE
RECOMMENDATIONS
The owner/operator is responsible for making sure that all
periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine
Maintenance
See engine manual for instructions.
Generator
Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. W ater
and dirt buildup on the generator windings wilt eventually
decrease the insulationresistance of these windings.
To Clean the Generator
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
STORAGE
The generator should be started at least once every seven
days and allowed to run at least30 minutes. If this cannot
be done and you must store the unit for more than 30
days, use the following guidelines to prepare it for storage.
Generator
Storage
• Clean the generator as outlined in "To Clean the
Generator."
• Check that cooling air slots and openings on generator
are open and unobstructed.
_
DANGER!
Storage covers can be flammable. Do
Not place a storage cover over a hot generator. Let
the unit coot for a sufficient time before placing the
cover on the unit
Engine Storage
See engine
owner's
manual
for instructions.
Other
Storage Tips
• Do
Not
store gasoline
from
one season
to another.
• Replace your
gasoline
can if it starts
to rust.
Rust and/or
dirt
in a gasoline
can cause problems
when you
use that
fuel with this unit.
• Store in clean and dry area.
SPECIFICATIONS
Maximum Surge Watts .................
6,875 watts
Continuous Wattage Capacity ...........
5,500 watts
Power Factor ..............................
1.0
Rated Maximum Continuous Load Current
At 120 Volts .......................
45.8 Amps
At 240 Volts .......................
22.9 Amps
Phase .................................
I -phase
Rated Frequency .......................
60 Hertz
Fuel Tank Capacity ..................
7 U.S.gallons
/
12
Need help?
Do you have a question about the 5500XL and is the answer not in the manual?
Questions and answers
does the generator need lubrication & if so where are the lub points
The Generac Power Systems 5500XL generator does not require additional lubrication for the revolving field, as it rides on a pre-lubricated and sealed ball bearing. However, the engine itself must be properly filled with the recommended oil before starting. The lubrication point for the engine is the oil fill cap.