Environmental Limits; System Environment Limits; System Environmental Testing; Table 99. System Environment Limits Summary - Intel P4000IP Series Technical Product Specification

Server system/workstation system
Hide thumbs Also See for P4000IP Series:
Table of Contents

Advertisement

Intel® Server System P4000IP and Intel® Workstation System P4000CR Family TPS
6.

Environmental Limits

6.1

System Environment Limits

The following table defines the Intel
P4000CR system level operating and non-operating environmental limits. Operation of the
®
Intel
Server System P4000IP and Intel
those shown in the following table may cause permanent damage to the system. Exposure to
absolute maximum rating conditions for extended periods may affect system reliability.
Parameter
Temperature
Operating
Non-Operating
Humidity
Non-Operating
Shock
Operating
Unpackaged
Packaged
Vibration
Unpackaged
Packaged
AC-DC
Voltage
Frequency
Source Interrupt
Surge Non-
operating and
operating
Line to earth
Only
ESD
Air Discharged
Contact
Discharge
Acoustics
Sound
Power
Measured
Power in Watts
Servers/Rack
Mount BA
Note:
1.
Intel Corporation server boards contain a number of high-density VLSI and power delivery
components that need adequate airflow to cool. Intel ensures through its own chassis development
and testing that when Intel
meet the intended thermal requirements of these components. It is the responsibility of the system
Revision 1.0
®
Server System P4000IP and Intel
®
Workstation System P4000CR at conditions beyond

Table 99. System Environment Limits Summary

1
10º C to 35º C
(50º F to 95º F) with the maximum rate of change not to exceed
10° C per hour
-40º C to 70º C (-40º F to 158º F)
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures
from 25° C to 35° C)
Half sine,
2g ,
11 mSec
Trapezoidal,
25 g
, velocity change is based on packaged weight
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
5 Hz to 500 Hz
2.20 g RMS random
5 Hz to 500 Hz
1.09 g RMS random
90 Hz to 132 V and 180 V to 264 V
47 Hz to 63 Hz
No loss of data for power line drop-out of 12 mSec
Unidirectional
AC Leads
2.0 kV
I/O Leads
1.0 kV
DC Leads
0.5 kV
12.0 kV
8.0 kV
≥300 W
<300 W
7.0
7.0
®
server building blocks are used together, the fully integrated system will
Intel order number G38159-001
®
Limits
≥600 W
≥1000 W
7.0
7.0
Environmental Limits
Workstation System
95

Advertisement

Table of Contents
loading

Table of Contents