2.10 System Level Environmental Limits; Table 5. System Environmental Limits Summary - Intel R1000SPO Series Technical Product Specification

Hide thumbs Also See for R1000SPO Series:
Table of Contents

Advertisement

2.10 System Level Environmental Limits

The following table defines the system level operating and non-operating environmental limits.
Parameter
Operating
Temperature
Shipping
Altitude
Operating
Humidity
Shipping
Operating
Shock
Unpackaged
Packaged
Unpackaged
Vibration
Packaged
Voltage
Frequency
Source Interrupt
Surge Non-
AC-DC
operating and
operating
Line to earth Only
Air Discharged
ESD
Contact Discharge
Power in Watts
Acoustics
Servers/Rack
Sound Power
Mount Sound
Measured
Power Level (in
BA)
17
Intel® Server System R1000SPO Product Family TPS

Table 5. System Environmental Limits Summary

ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum
rate of change not to exceed 10°C per hour
ASHARE Class A3 – Includes operation up to 40°C for up to 900 hours per year. Refer to
Appendix E for detailed guidance.
-40º C to 70º C (-40º F to 158º F)
Support operation up to 3050m with ASHRAE class de-ratings.
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25°
C to 35° C)
Half sine, 2 g, 11 mSec
Trapezoidal, 25 g, velocity change is based on packaged weight
ISTA (International Safe Transit Association) Test Procedure 3A 2008
5 Hz to 500 Hz
2.20 g RMS random
ISTA (International Safe Transit Association) Test Procedure 3A 2008
90 V to 132 V and 180 V to 264 V
47 Hz to 63 Hz
No loss of data for power line drop-out of 12 mSec
Unidirectional
AC Leads
2.0 kV
I/O Leads
1.0 kV
DC Leads
0.5 kV
12.0 kV
8.0 kV
<300 W
≥300 W
7.0
7.0
Limits
≥600 W
≥1000 W
7.0
7.0

Advertisement