Oki B410 Maintenance Manual page 104

Hide thumbs Also See for B410:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
① The case where the printer does not work normally after tuning on the power
• Turn off the power and then, turn on the power again.
• Are messages in the display of LCD all in black?
• Yes
• Yes
• Yes
43984801TH Rev.1
• NO
Is the AC cord properly connected?
• NO
Connect the AC cord.
• Yes
Is the cable to connect the main board with the low-voltage power correctly
connected?
• No
Connect the cable.
• Yes
Is +5V supplied to the main board?
(Check with 18 pins and 35 pins of CENT connector)
• No
• Yes
• Yes
The flexible cable of the operator panel Assy is appropriately connected to the
LCDPNL connector of the main board and Connector CN1.
• No
Connect the flexible cable appropriately.
• Yes
Replace the operator panel Assy or the flexible cable.
• Has the problem been solved?
• No
Replace the main board.
• Yes
Completed
Is the message of "INITIALIZING" displayed on the LCD?
• No
Replace the main board.
Is the message of "ONLINE" is displayed on the LCD?
• No
Take action according to the LCD status message/ Trouble List. (Refer
to the Section 6.5.1 for how to take action.)
Completed.
Do+5V of the main board and GND short out?
(Check with 18 pins and 35 pins of CENT connector)
No
Replace the low-voltage power.
Replace the main board.
6. Procedures for Repairing
104 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B430B420Mps420b

Table of Contents