Clearances - Montigo 30FID Installation & Maintenance Manual

I-series indoor residential fireplace insert
Table of Contents

Advertisement

Clearances:

The 30DFIDV-LIN Insert is designed and built to be installed into
masonry or manufactured fireplaces. There is no requirement to
have a non-combustible hearth in front of the unit. Clearances
to the underside of the mantel or sidewall are measured from
the edge of the door/screen front. The Mantel is shown as 10"
maximum at a distance of 16" minimum from the door edge top.
The mantel can be extended further providing that you increase
the height proportionately. For instance, if you want a mantel that
is 2" beyond the 10" maximum, you have to install it 2" above the
16" minimum.
Figure 2 Sec.2
30DFID-L clearances
8"
4"
38"
36"
34"
32"
30"
28"
26"
24"
22"
20"
18"
16"
Figure 3 Sec.2
30DFID-L mantel clearances
XG0513-092314
Installation
Min
12"
16"
20"
24"
28"
32"
Allowable
Mantel
Area
10"
254
Max
16"
406
Min
I-Series Indoor Gas Fireplace
Page 11