Door Installation & Removal - Montigo 30FID Installation & Maintenance Manual

I-series indoor residential fireplace insert
Table of Contents

Advertisement

I-Series Indoor Gas Fireplace
Door Installation & Removal
This appliance is supplied with a safety screen installed. The
Safety Screen is attached to the fireplace door using 4 screws,
and can be removed when necessary for outer glass cleaning.
The Fireplace Door is attached to the Firebox by way of 2 tabs
mounted to the top of the Firebox and by 2 spring loaded retainers
at the bottom underneath the Door. The Retainers at the bottom
of the unit are manipulated using a Door Tool that is supplied with
the unit. The general operation of the Door Retainers is:
a). Engage the Door Tool into the Door Retainer
b). Pull forward away from the tabs that engage it on the
bottom of the Door Frame
c). Move the retainer downward and then back underneath
the Door
d). Swing the Door outward from the unit and then lift the
Door up and over the top Tabs.
Figure 5 Sec.4 Door Tool / Bottom of Door
Engage door tool into door retainer. Pull door tool towards you and
push downwards, disengaging the door retainer from the door.
Figure 6 Sec.4 Engaging the Door Tool Into the Door Retainer
Page 16
Installation
Figure 7 Sec.4 The door latch released from the Door
Figure 8 Sec.4 Swing the Door away from the unit, lift over the retaining
tabs on top of the firebox. Be careful to not roll the gasket up off the glass
when reinstalling the door.
Figure 9 Sec.4 Location of Door retainer tabs
Check that the door retainers are properly engaged. If they are
not the door relief system may not operate properly. This can
cause a risk of injury or improper operation of the appliance.
XG0513-092314