Montigo 36DV-TV Installation And Operation Manual
Montigo 36DV-TV Installation And Operation Manual

Montigo 36DV-TV Installation And Operation Manual

Gas-burning fireplace

Advertisement

INSTALLING AND OPERATING
YOUR MONTIGO 36DV-TV
GAS-BURNING FIREPLACE
Please leave this manual with the owner
CHECK LOCAL CODES PRIOR TO INSTALLATION
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. OPEN WINDOWS.
2. DON'T TOUCH ELECTRICAL SWITCHES.
3. EXTINGUISH ANY OPEN FLAME.
4. IMMEDIATELY CALL YOUR GAS SUPPLIER.
READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING
CANADIAN HEATING PRODUCTS INC.
12091 88th Avenue, Surrey, B.C. Canada; Phone: (604) 597-3115 Fax: (604) 597-3096
11/93
MODEL
MONTIGO 36DV-TV
FOR YOUR SAFETY:
DO NOT STORE OR USE ANY FLAMMABLE
VAPOURS OR LIQUIDS NEAR THIS OR ANY
OTHER GAS-BURNING APPLIANCE.
Page 1 of 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 36DV-TV and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo 36DV-TV

  • Page 1 INSTALLING AND OPERATING YOUR MONTIGO 36DV-TV GAS-BURNING FIREPLACE Please leave this manual with the owner CHECK LOCAL CODES PRIOR TO INSTALLATION FOR YOUR SAFETY FOR YOUR SAFETY: IF YOU SMELL GAS: 1. OPEN WINDOWS. DO NOT STORE OR USE ANY FLAMMABLE 2.
  • Page 2: Installing The Fireplace

    The Montigo 36DV-TV clearances to combustible materials are Natural & Propane gas. 0" back, 1" sides, 0" floor and 4" top. The Montigo 36DV-TV must The Montigo warranty will be voided by, and Montigo disclaims not be installed any closer than 8 inches to any unprotected any responsibility for, the following actions: combustible wall perpendicular to the fireplace opening.
  • Page 3 INSTALLATION OF DIRECT VENT This section is used to determine where your direct vent termination will be located. A complete Montigo 36DV-TV vent system may comprise of six individual components: (see figure 5. page 4) VENT TERMINATIONS SHALL NOT BE RECESSED IN WALLS OR SIDING.
  • Page 4: Horizontal Venting

    7 1/2 ft. from center of fireplace 10 ft. from center of elbow Solid section includes 90 degree elbow Stucco Can Vent Termination 3 ft. flex section 10" 4" Hearth 43" FIGURE 7. RETRACTED 10' SECTION 3, or 4 ft. flex section FIGURE 5.
  • Page 5 INSTALLATION OF VERTICAL DIRECT VENT Storm collar 2 Feet Roof flashing A complete Montigo 36DV-TV vertical vent installation may comprise of the following components: A - Termination MVTK-1 B - Flex sections MFL-1 (1' 6" section) Support ring MFL-2 (2' 6" section) Support plate MFL-3 (3' 6"...
  • Page 6: Venting Graph

    Venting graph is used for top vent direct vent model only. How to use the venting graph: The Montigo 36DV-TV is equipped with a remote-operated valve, located behind the removable brass grille, to the right of the gas 1 Determine the height for the centre of the 7" vent elbow and mark a horizontal line until it intersects control valve (refer to figure 14.) The valve is pre-wired and...
  • Page 7: Mantels And Surrounds

    FIREPLACE MANTEL AND FACING MANTELS & SURROUNDS NOTE: National Canadian Gas Association mantel test require- Combustible mantels and mouldings may be safely installed over ments are for fire hazard prevention to combustible materials. the top and on the front of the fireplace provided that they do not project beyond shaded area shown in figure 10A.
  • Page 8: Installing Log Set

    INSTALLING LOG SET Easily removed for cleaning and servicing. Although this pane is The Montigo 36DV-TV is supplied with four(4) very attractive made of a very tough tempered glass, always handle it carefully and cultured oak logs. To install simply place log “A’s” rectangular place in a safe location where it will not be broken or damaged.
  • Page 9: Pilot Burner Adjustment

    It is imperative that burner control compartments, burners and circulating air passageways of the appliance be kept clean. For If your Montigo 36DV-TV still does not operate correctly, consult your convenience a 1/8" pressure tap is supplied on the gas valve your dealer or the manufacturer.
  • Page 10 Canadian Heating Products Inc. warrants the Montigo 36DV Decorative Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo 36DV there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner, pilot burner and cultured oak logs, and a one-year warranty on the gas control valve and glass doors.

Table of Contents