STOPPING THE ENGINE IN EMERGENCY

IMPORTANT: Normally, use the engine stop switch (1)
to stop the engine. Use the emergency
engine stop switch (2) only for
emergency stops, or if the engine stop
switch (1) malfunctions. If the engine is
shut off without cooling down, the
turbocharger free-wheels without
receiving lubricant, resulting in serious
damage to the turbocharger.
1. Turn emergency engine stop switch (2) from the
NORMAL position to the EMERG STOP position
when emergency engine stop is required in the cab.
2. Engine will stop simultaneously and emergency stop
indicator (3) will come ON. In addition, the air
pressure is bled from the hydraulic oil tank.
3. Turn emergency engine stop switch (2) to the
NORMAL position and return the conditions to the
normal engine stop before attempting to restart the
engines.
NOTE: Do not use emergency engine stop switch (2) in
cab when performing any inspection/service
work. Use emergency engine stop switches at
the area where any inspection/service works
are performed to avoid possible personal injury.
Other engine stop switches are shown next
module.
OPERATING THE ENGINE