Replacing Fuses --- as required
If any electrical component fails, first check the fuses in
the fuse box, located in room (A) under the cab. Re-
move fuse box cover and confirm that the fuses shown
below are provided.
IMPORTANT: Install fuse with correct amperage rating
to prevent electrical system damage
from overload.
1- MC MAIN POWER 5A
2- DELAYED POWER OFF RELAY
5A
3- -----
4- MMS BACKUP 5A
5- HMU MAIN POWER 5A
6- AIR HORN COMPRESSOR (L)
30A
7- AIR HORN COMPRESSOR (R)
30A
8- FOLDING STAIRWAY SOL(A) 10A
9- BOX LIGHT 5A
10- CAB. BATTERY POWER 30A
MAINTENANCE
11- OPT. C/U MAIN POWER 10A
12- OPT. C/U MAIN POWER 10A
13- OPT. C/U KEY ON SIG. 5A
14- OPT. C/U KEY ON SIG. 5A
15- MC KEY ON SIG. 5A
16- ELU PWM POWER RELAY 5A
17- DLU OPT. KEY SW ON SIG. 5A
18- ------
19- ECM LAMP POWER 5A
20- HMU KEY ON SIG. 5A
A
1
2
3
11
12 13 14 15
21
22 23 24 25 26
31
32
M18M-07-054
21- WASHER MOTOR RELAY 5A
22- TRAVEL SPEED SELECT RELAY
5A
23- A/C MAIN RELAY (FRONT) 5A
24- A/C MAIN RELAY (SIDE) 5A
25- A/C MAIN RELAY (REAR) 5A
26- BATTERY RELAY 5A
27- A/C CONTROL AMP (FRONT) 5A
28- A/C CONTROL AMP (SIDE) 5A
29- A/C CONTROL AMP (REAR) 5A
30- MOTION ALARM 5A
7-109
4
5
6
7
17 18
16
27 28
33 34 35 36
37 38
31- A/C MAIN POWER (FRONT)
15A
32- A/C MAIN POWER (SIDE) 15A
33- A/C MAIN POWER (REAR) 15A
34- A/C C. FAN (FRONT) 20A
35- A/C C. FAN (SIDE) 20A
36- A/C C. FAN (REAR) 20A
37- DLU SERVICE TOOL 5A
38- ORBCOMM MAIN PAWER 5A
39- MMS MAIN PAWER 5A
40- CHARGE SIG. 5A