Check Tightening Torque
--- every 250 hours
Check the tightness of mounting bolts, hose connections
and fittings every 250 hours. Tighten to torque specifica-
tions if any are loose.
Torque Specifications for Hose Connections:
Wrench
Size
N⋅m
(mm)
19
11.5 to 14.5
24
19.5 to 24.5
27
29.5 to 34
Torque Specifications for Compressor Mounting Bolts:
Wrench
Size
N⋅m
(mm)
10
19.5 to 29.5
Torque Specifications for Liquid Tank:
Wrench
Size
N⋅m
(mm)
10
7.8 to 11.5
MAINTENANCE
Fastening Torque
(kgf⋅m)
(1.2 to 1.5)
(8.7 to 10.5)
(2 to 2.5)
(14.5 to 18)
(3 to 3.5)
(21.5 to 25.5)
Fastening Torque
(kgf⋅m)
(2 to 3)
(14.5 to 21.5)
Fastening Torque
(kgf⋅m)
(0.8 to 1.2)
(5.8 to 8.7)
(lbf⋅ft)
(lbf⋅ft)
(lbf⋅ft)
7-102