Stopping The Engine - Hitachi 120-3 class Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

STOPPING THE ENGINE

Engine stop procedure
1. Park the machine on a level surface.
2. Lower the bucket to the ground.
3. Turn engine control dial (1) to the slow idle position and
run the engine for 5 minutes to cool the engine.
IMPORTANT: Turbocharger may be damaged if the engine
is not properly shut down.
4. Turn key switch (2) OFF. Remove the key from the key
switch.
5. Pull pilot control shut-off lever (3) to the LOCK position.
If the engine does not stop with the key switch turned in
the OFF position
In case the engine does not stop even if the key switch is
turned OFF due to failure of the machine, move engine stop
switch (4) downward to stop the engine.
CAUTION: Do not use the emergency stop switch,
except when unavoidable.
Moreover, Do not operate the machine until repair is
completed when stopping the engine with the failure
of the machine.
OPERATING THE ENGINE
3-10
3
Slow Idle
2
4
SA-390
M1U1-01-025
1
M1U1-01-033
M178-01-049
M1U1-01-029

Advertisement

Table of Contents
loading

Table of Contents